4–2
Installing Your Hardware
Installing the System
Hardware
Publication 2755-6.9
Refer to the following steps to install your system hardware properly.
1. Make sure your scanner system is planned out properly. Refer to
chapter 3 for information regarding planning your scanner
system.
2. Mount the reader (Catalog Nos. 2755-LS7-SA, 2755-LS7-SB,
2755-LS7-RA, 2755-LS7-RB, 2755-LS7-SBV, or
2755-LS7-RBV) to the mounting plate (Catalog No.
2755-LS7-N) or directly to your mounting surface.
The dimensions of the reader are shown on the next page. The
dimensions of the mounting plate are shown below.
The maximum distance from the reader to another device is 3 ft.
(0.91 m). Use # 6 screws with maximum penetration of 0.15 in.
(3.81 mm). If you are not using the mounting plate, go to step #4.
Note: The drawing below is not to scale.
2.08 in. (5.30 cm)
2.58 in. (6.57 cm)
1.26 in. (3.21 cm)
Reader
Mounting Plate
2.60 in. (6.62 cm)
2.39 in. (6.08 cm)
3.85 in. (9.77 cm)
4.35 in. (11.04 cm)