5–32
Configuring Your Reader
Command
End of Read Cycle Mode
0 = Timeout
1 = New Trigger
2 = Timeout and New Trigger

External Trigger Level

0 = Negative
1 = Positive
Status
0 = Disabled
1 = Enabled
2 = Sequential
3 = Wild Card
Sequential Matching
0 = Increment
1 = Decrement
Match Start Position
0 to 64. 0 is the
default.
Match Length
1 to 64. 1 is the
default.
Wild Card Character
Any character. *
(asterisk) is the
default.
Publication 2755-6.9
End of Read Cycle. The timeout occurs in 10 millisecond
increments. You can use any number between zero and 65535.
The default is 100 (one second).
Parameter
Kh
Serial Trigger Character. You can use any available ASCII
character. The default character is ^. Pressing
the default character with the serial triggering mode selected, will
trigger the reader.
Parameter
Ki
External Trigger Level
Command
Parameter
Kj
Kj
Good Decode Reads. You can use any number between 1 and 31.
The default is 1.
Parameter
Km
Match Code Type
Command
Parameter
Kn
Kn
Format
To select Timeout and change the
<Khend of read cycle
<Khend of read cycle
timeout value to 6 seconds, press
mode,timeout>
[<Kh0 600>]
[<Kh0,600>].
Format
To define the Serial Trigger Character as
<Kiserial trigger character>
a lower case c, press [<Kic>].
Format
To change External Trigger Level to
<Kjexternal trigger level>
<Kjexternal trigger level>
negative, press [<Kj0>].
Format
To change Good Decode Reads to 3,
<Kmnumber of reads>
press [<Km3>].
Format
<Kntype,sequential
<Kntype,sequential
To enable Match Code Type for
matching,match start
Sequential, set Sequential Matching for
position,match length,wild
Decrement, and enable Sequence on
Decrement, and enable Sequence on
card character,sequence
Every Mismatch, press
on no read,sequence on
[<Kn2,1,,,,,1>].
[<Kn2,1,,,,,1>].
every mismatch>
Example
when using
[<^>]
Example
Example
[<Kj0>]
Example
Example

Advertisement