5–20
Configuring Your Reader
Publication 2755-6.9

Scanner Output Menu

The Scanner Output menu, shown below, allows you to configure the
reader's output. Default settings are in bold type face.
Bar code output data and no read messages are transmitted on pin 2
under conditions set principally in Bar Code Output.
Relay pulses are transmitted via pins 7 and 14 (Relay-1 and Relay-2,
respectively) and individually configured under conditions set in
Relay-1 and Relay-2.
Relay-1 and Relay-2 can allow simultaneous output under
individually programmed conditions.
Scanner Output
Relay-1
Relay-2
Output On
Mismatch or No Read
Match
(or Good Read)
Mismatch
No Read
When to Output
Bar Code
Output
As Soon As
Possible
Good Read
End Of Read
Disabled
Cycle
Match
Mismatch
Beeper Status
Beeper Volume
On Good
Level 4
On No Read
Level 5
Off
Level 1
Level 2
Level 3
Partial Output
Status
Start Position
Disabled
1
Enabled
User Definable
(1 to 63)
Divide the number entered on the command line by 100 for time in seconds.
Polarity
Negative
Positive
No Read Message
No Read Output
7 digits
Enabled
No Read
Disabled
User Definable
(ASCII char.)
Full Screens
Enabled
Disabled
Length
63
User Definable
(1 to 63)
Pulse Width
(in 10 ms incs)
50 ms
User Definable
(0 to 255)
Laser On/Off
Disabled