OPERATION

Programming
Normal display will read "Ready"
Press and hold "Cancel" button (red lights will alternate on Keg and gas empty)
Display will show pint and jugs dispensed. (these readings cannot be altered).
Press "Portion 2" button to scroll trough the menu:
Press "Portion 2" display will read "pint set up"
Press "Portion 2" display will read "Jug set up"
Use the "Portion 1" and "Top up" buttons to alter value (this applies to all settings)
Press "Portion 2" display will read "Hit (ms)" 100 – Do not alter this value
Press "Portion 2" display will read "Hold (%) 020 – Do not alter this value
Press "Portion 2" display will read "Pint Timeout" – Do not alter this value
Press "Portion 2" display will read "Jug timeout" 40.0 – Do not alter this value
Press "Portion 2" display will read "Drain Time" 03.0 – Do not alter this value
Press "Portion 2" display will read "Drain delay" 100 - Do not alter this value
Press "Portion 2" display will read "Beer saver" 3500 - Do not alter this value
Press "Portion 2" display will read "Top up valves 2. Alter between 1 valve or two valves. 1 is
for foam, 2 is for clear beer.
To exit the program press "Cancel"