Installation Manual
PPT8/12/16/22L/LY

5.2 Remote Thermostat

Calorex Heat Pumps Ltd. · The Causeway, Maldon, Essex CM9 4XD, UK · Tel: +44 (0)1621 857 171
A remote thermostat kit is available which allows the user of the heat
pump to control the setting of the heat pump away from the heat pump, for
example from inside the home. Please note the thermostat is rated at IP40
and is not suitable for outdoor use.
NOT USED
ACCESS SET POINT
With the heat pump isolated electrically, remove lid from heat pump and
disconnect the links as shown. Connect wires between heat pump and
remote thermostat as shown in the diagram below. See label inside
thermostat cover for further information. When correctly connected replace
lid of heat pump and restore power to the heat pump.
SENSOR LEADS TO BE
RUN SEPARATELY
10 11
1213 14 15
REMOVE LINKS AND WIRE TO
TERMINAL SHOWN
ILLUMINATED LAMP DENOTES HEATING
To Change the temperature press and release the P key to display
required temperature, to alter required temperature press the up or down
keys. After 5 seconds the display reverts to actual water temperature.
Page 16
INCREASE SET POINT
DECREASE SET POINT
16 17 18 19 20 21
1 2
R
3 4
6
7 8 9 10 1112
23.1