Example 3 : Dbm Measurement - Rigol DM3000 Series Programming Manual

Dm3000 series digital multimeter
Hide thumbs Also See for DM3000 Series:
Table of Contents

Advertisement

RIGOL

Example 3 : dBm Measurement

Purpose: To achieve dBm measurement.
dBm is a commonly measure units which widely used in electrical, radio, mechanics,
shock and vibration, mechanical power and acoustics, and other fields, and dBm
caluation is usually used for RF signal measurement.
The programming steps:
0
*RST
1
*IDN?
2
:function:resistance
3
:measure□AUTO
4
:measure:resistance?
/*measure the reference resistance for dBm calculation*/
5
:function:voltage:AC
6
:measure□AUTO
7
:calculate:function DBM
8
:calculate:DBM:reference □ <value>
calculation*/
9
:calculate:DBM?
Remark:
1.
Before sending the fourth command, please connect equipment according to
resistance measure type.
2.
The parameter of eighth command is the above measurement resistance.
4-4
/*reset */
/*query equipment ID*/
/*turn on 2WR measure function*/
/*set resistance measurement as auto*/
/*query the resistance*/
/*turn on AC voltage measure function*/
/*set AC voltage measurement as auto*/
/*turn on dBm calculation function*/
/*query the dBm value*/
Programming Guide for DM3000 Series
/*set reference voltage for dBm
© 2008 RIGOL Technologies, Inc.