Page 2
2. RIGOL products are protected by patent law in and outside of P.R.C.. 3. Information in this publication replaces all previously corresponding material. 4. RIGOL TECNOLOGIES, INC. reserves the right to modify or change part of or all the specifications and pricing policies at company’s sole decision.
Page 3
If suspected damage occurs with the instrument, have it inspected by qualified service personnel before further operations. Keep Well Ventilated. Do Not Operate in Wet/Damp Conditions. Do Not Operate in an Explosive atmosphere. User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Page 4
NOTE: Voltage on the current input terminal corresponds to voltage on LO terminal. To obtain favorable protection, specified fuse should be used. IEC Measurement Category II Overvoltage Protection To protect against the danger of electric shock, DM3058/DM3058E provides overvoltage protection for line-voltage mains connections meeting both of the following conditions: 1....
Page 5
DM3058/DM3058E may be used to make measurements with the HI and LO inputs connected to mains in such devices (up to 600 VAC), or to the branch outlet itself.
Page 6
Symbols on the Product. These symbols may appear on the product: Protective Hazardous Safety Chassis Test Earth Voltage Warning Ground Ground Terminal User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Page 7
The DM3058/DM3058E holds a 256 x 64 lattice high-resolution monochrome LCD display screen with clear keyboard layout and operation hints to make it easier and agility to use. Besides, it supports multi-interface such as RS-232, USB, LAN (only for DM3058) and GPIB (only for DM3058).
Page 8
Backup or “Clone” all the configurations within instrument into other DM3058/DM3058E via USB flash device. Chinese and English menu and online help system. Provides with control software on PC and application software for sensor.
Page 9
RIGOL Document Overview Chapt 1 Quick Start Guide you to prepare your DM3058/DM3058E and know about the Front/Rear Panel and User interface. Chapt 2 Panel Operation Introduce you how to operate DM3058/DM3058E via Front Panel. Chapt 3 Application Examples Introduce you how to use strong measurement functions of this instrument easily through examples.
RIGOL Contents DM3058/DM3058E Overview ................ VI Chapter 1 Quick Start ................1-1 General Inspection ..................1-2 Handle Adjustment ..................1-3 The Front Panel ..................1-4 The Rear Panel ..................1-5 Power On ....................1-6 User Interface ................... 1-7 Double Display ..................1-7 Single Display ..................
Page 11
Application of the Analog Filter ..............5-5 Chapter 6 Characteristics ..............6-1 General Technical Characteristics ..............6-1 Electric Technique Characteristics ............... 6-2 DC Characteristics ................6-2 AC Characteristics ................6-4 Frequency/Period Characteristics ............6-7 Capacitance Characteristics ..............6-8 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Page 12
RIGOL Other Measurement Characteristics ............6-9 Chapter 7 Appendix ................7-1 Appendix A: DM3058/DM3058E Accessories ..........7-1 Appendix B: Warranty ................7-2 Appendix C: General Care and Cleaning ............7-3 Appendix D: Contact Us ................7-4 User’s Guide for DM3058/DM3058E 800.561.8187...
RIGOL Chapter 1 Quick Start General Inspection Handle Adjustment The Front Panel The Rear Panel Power On User Interface User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Representative. If the shipping container is damaged, or the protective material shows signs of stress, notify the carrier as well as your RIGOL sales office. Keep the shipping materials for the carrier’s inspection. RIGOL offices will arrange reparation or replacement at RIGOL’s option without waiting for claim settlement.
Then, rotate the handle to the desired position as shown in the figures below. Figure 1-1 Adjust Handle Level location Move location Figure 1-2 Adjustable location of Handle User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Yellow District: Trigger Control Keys Direction Keys LCD Display Gray District: Menu Blue District: Power Measurement Operation Keys Signal Input Terminal Assistant Function USB Host Function Keys Keys Figure 1-3 Front Panel Overview User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Current Input Fuse GPIB 10/100 Power Socket (IEEE--488) Ethernet USB Device RS-232 Power Fuse AC Voltage Power Switch Selector Figure 1-4 Rear Panel Overview Explanation: DM3058E does not support GPIB and LAN interfaces. User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
1. Adjust AC Voltage Selector to “115” (100~120V, 45~440Hz, AC) or “230” (200~240V, 45~60Hz, AC) in accordance with power standards in your country; 2. Connect the instrument to AC supply via power cord supplied by RIGOL; 3. Turn on the power switch on the rear panel;...
Rmt Remote Control Local Control Main Display Function USB Storage Run Direction Reading Display Vice Display Value Vice Display Function Menu Single Display Main Display Function Run Direction Reading Display Figure 1-5 User Interface User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
To Set up Measurement Parameters Math Functions To Set Up Trigger Parameters Store and Recall To Set Up the Utility How to Use the Built-in Help System User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Auto Range: Press Auto to choose Auto Range, meanwhile Manual Range is forbidden. Manual Range: Press Rng+ or Rng- to choose required range manually, at this moment, Auto Range is forbidden. Figure 2-2 Range selection menus User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Page 22
At the input interface of data, Left and Right keys are used to switch the number of a numerical value. Each press for the Left key, former number will be selected, vice versa. User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www.
The reading resolution and measurement rate of the Freq function are fixed at 5.5 digit and “Slow” respectively. The reading resolution and measurement rate of the Cap function are fixed at 3.5 digit and “Slow” respectively. User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
RIGOL Basic Measurement Functions DM3058/DM3058E contains following basic functions: To Measure DC Voltage To Measure AC Voltage To Measure DC Current To Measure AC Current To Measure Resistance To Measure Capacitance To Test Continuity ...
Figure 2-4 DC Voltage Measurement Interface Connect the red lead to terminal Input-HI and black lead to terminal Input-LO as the figure below. DC Voltage Figure 2-5 Sketch map for connecting User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Page 26
View history data Press History to enter into the following interface and check the data getting from this measurement and saved. Figure 2-6 View interface of history data User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Page 27
RIGOL There are three types of way for viewing historical date: “Info”, “List” and “HistoG”. Press Save after checking, by pressing Update, the History information will be refreshed to be current newest information. User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www.
Choose a proper Voltage range according to the measured circuit Table 2-2 Measurement Characteristics of AC Voltage Ranges* 200mV, 2V, 20V, 200V, 750V Input Protection on all ranges (HI terminal) Vrms Configurable Range, REL Parameters User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Page 29
There are three types of way for viewing historical date: “Info”, “List” and “HistoG”. Press Save after checking. By pressing Update, the History information will be refreshed to be current newest information. 2-10 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www.
Figure 2-11 DC Current Measurement Interface Connect the red lead to terminal Input-I and black lead to terminal Input-LO as the figure below. DC Current Figure 2-12 Sketch map for connecting User’s Guide for DM3058/DM3058E 2-11 800.561.8187 information@itm.com www. .com...
Page 31
There are three types of way for viewing historical date: “Info”, “List” and “HistoG”. Press Save after checking. By pressing Update, the History information will be refreshed to be current newest information. 2-12 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www.
Figure 2-14 AC Current Measurement Interface Connect the red lead to terminal Input-I and black lead to terminal Input-LO as the figure below. AC Current Figure 2-15 Sketch map for connecting User’s Guide for DM3058/DM3058E 2-13 800.561.8187 information@itm.com www. .com...
Page 33
There are three types of way for viewing historical date: “Info”, “List” and “HistoG”. Press Save after checking, by pressing Update, the History information will be refreshed to be current newest information. 2-14 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www.
Figure 2-17 2-Wire Resistance Measurement Interface Connect the red lead to terminal Input-HI and black lead to terminal Input-LO as the figure below. Resistance Figure 2-18 Sketch map for connecting User’s Guide for DM3058/DM3058E 2-15 800.561.8187 information@itm.com www. .com...
Page 35
There are three types of way for viewing historical date: “Info”, “List” and “HistoG”. Press Save after checking, by pressing Update, the History information will be refreshed to be current newest information. 2-16 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www.
Page 36
Connect the red leads to terminal Input-HI and HI Sense and black leads to terminal Input-LO and LO Sense as the figure below. 4-Wire Sense HI Resistance 4-Wire Sense LO Figure 2-21 Sketch map for connecting User’s Guide for DM3058/DM3058E 2-17 800.561.8187 information@itm.com www. .com...
Page 37
There are three types of way for viewing historical date: “Info”, “List” and “HistoG”. Press Save after checking. By pressing Update, the History information will be refreshed to be current newest information. 2-18 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www.
Page 38
NOTE Please do not put the terminals of the resistance on the conductive plane or in your hand to avoid error. The bigger of the resistance, the more affection it will be brought. User’s Guide for DM3058/DM3058E 2-19 800.561.8187 information@itm.com www.
RIGOL To Measure Capacitance The DM3058/DM3058E Digital Multimeter has the ability to test Capacitance up to 10000μF. Following practice provides you a guide to get familiar with the Capacitance measurement technique. Operating Steps: Press to enter into Capacitance measurement interface.
Page 40
NOTE Before measuring the electrolytic capacitance, you should make the two legs of the electrolytic capacitance short circuit and let it be discharged. User’s Guide for DM3058/DM3058E 2-21 800.561.8187 information@itm.com www.
When the measured resistance in circuit is lower than selected one, it is considered being connected by instrument. Next, we will introduce you how to test continuity for circuit by using DM3058/DM3058E step by step to make you familiar with this technique.
Page 42
RIGOL Table 2-8 Continuity Measurement Characteristics Test Current Range Fixed at 2kΩ Open-circuit Voltage <8V Input Protection 1000V (HI terminal) 0≤R ≤Short-circuit impedance; testing Beep Condition 1Ω≤Short-circuit impedance≤2kΩ User’s Guide for DM3058/DM3058E 2-23 800.561.8187 information@itm.com www. .com...
When connecting, the instrument will beep one time (If Sound is open). Table 2-9 Check Diodes Characteristics Test Current Range Fixed at 2.0V Open-circuit Voltage <8V Input Protection 1000V (HI terminal) Beep Condition 0.1V≤V ≤2.0V measured 2-24 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Figure 2-30 Frequency Measurement Interface Connect test leads as the figure below. Red test lead connects with terminal HI; Black test lead connects with terminal LO. AC Signal Figure 2-31 Sketch map for connecting User’s Guide for DM3058/DM3058E 2-25 800.561.8187 information@itm.com www.
Page 45
There are three types of way for viewing historical date: “Info”, “List” and “HistoG”. Press Save after checking. By pressing Update, the History information will be refreshed to be current newest information. 2-26 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www.
Connect the red lead to terminal-HI and black lead to terminal LO as the figure below. AC Signal Figure 2-34 Sketch map for connecting Table 2-11 Period Characteristic Ranges 200mV, 2V, 20V, 200V, 750V Measurement Range 1μs~0.05s Input Protection 750V (HI) Configurable Parameters User’s Guide for DM3058/DM3058E 2-27 800.561.8187 information@itm.com www. .com...
Page 47
There are three types of way for viewing historical date: “Info”, “List” and “HistoG”. Press Save after checking. By pressing Update, the History information will be refreshed to be current newest information. 2-28 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www.
Sensor is shown on the screen directly and you can edit or modify its display unit at will. The multimeter supports DCV, DCI, and Freq, 2WR, 4WR and Thermocouple TC 6 kinds of Sensor in all. Meanwhile, there are 10 groups of basic Sensor preset within the instrument. User’s Guide for DM3058/DM3058E 2-29 800.561.8187 information@itm.com www.
Page 49
Figure 2-36 Sketch map for connecting As the Current Sensor, please connect the red lead to terminal Input-I and black lead to terminal Input-LO as the figure below. Sensor Figure 2-37 Current Sensor Connecting 2-30 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Page 50
Open/Close Relative Operation Disp Set sensor measurement display mode Press New to create a new Sensor. Figure 2-39 New interface (1) Press Prpty to enter into the input interface. Figure 2-40 Property Interface User’s Guide for DM3058/DM3058E 2-31 800.561.8187 information@itm.com www. .com...
Page 51
User-defined unit is limited within two characters. Switch to the character which needs to be edited by the left/right direction keys. Select required characters by the up/down direction keys from A-Z and a-z. 2-32 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www.
Page 52
Arithmetic of current data Figure 2-46 View interface of Reference data Repress Add to input second group of data. From this group you can press SEG “Open” Arith and select arithmetic. User’s Guide for DM3058/DM3058E 2-33 800.561.8187 information@itm.com www. .com...
Page 53
Figure 2-50 Save Interface Press and return to the New interface. Press Apply as shown in figure 2-48 and load settings into current Sensor and use it directly. 2-34 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Page 54
(select Meas); only display the corresponding result (select Corrsp); when All is selected, the measured result will be shown on the Vice display and the corresponding result will be shown on the Main display. User’s Guide for DM3058/DM3058E 2-35 800.561.8187 information@itm.com...
Page 55
RIGOL Figure 2-54 Display mode Figure 2-55 Display the value 2-36 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Setn, current measurement configuration would be saved into corresponding location and named “Setn” as a default. Besides, you can also recall or save preset configuration by using function. User’s Guide for DM3058/DM3058E 2-37 800.561.8187 information@itm.com www. .com...
(2) If different measurement functions are used in both Main and Vice Display The readings in both of the display will update alternately. If Math function (STA, P/F, dBm and dB) is used in Main Display, when open 2-38 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Page 58
(see the Store and Recall section). 3. Open REL Settings Interface Quickly In general measurement interface, press , then press the REL menu to enter Figure 2-65 Relative operation setting interface immediately. User’s Guide for DM3058/DM3058E 2-39 800.561.8187 information@itm.com www. .com...
Holding Trigger Press key, it allows capturing and holding a stable reading on the front panel display. NOTE Press in Remote Mode to switch back to the local mode. 2-40 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
If AC component existing in inputted DC signal, it can be filtered by AC Filter so as to make the data more exactly. Figure 2-57 Open/Close AC Filter User’s Guide for DM3058/DM3058E 2-41 800.561.8187 information@itm.com www.
200mV and 2V measurement range is >10GΩ; for 20V, 200V and 1000V measurement range is kept at 10MΩ. The DC input impedance default is 10 MΩ; settings of DC input impedance are stored in the nonvolatile memory. 2-42 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Page 62
The range of short-circuit resistance is 1Ω~2000Ω. The default value is 10Ω. The short-circuit resistance value is stored in the nonvolatile memory and the resistance remains unchanged after power-off. User’s Guide for DM3058/DM3058E 2-43 800.561.8187 information@itm.com www. .com...
The dB measurement is the difference between the input signal and a stored relative value. Turn on /Turn off the REL function. Save all changes, back to a higher level menu. 2-44 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
When getting more readings, current displaying value is always the maximum/minimum reading among all the measured values. The maximum, minimum, average and reading quantities are stored in volatile memory. User’s Guide for DM3058/DM3058E 2-45 800.561.8187 information@itm.com www.
Up and Down Direction keys. 2. Unit The unit of P/F is decided by the current measurement function. 3. Over P/F hint When the readings exceed selected upper limit, the vice-scream will show “HI FAIL”. 2-46 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Page 66
The upper limit value should be always bigger than the lower limit value. The upper and lower values are stored in volatile memory. They will be set to defaults when power on. User’s Guide for DM3058/DM3058E 2-47 800.561.8187 information@itm.com www.
Open dBm Measurement. Status bar shows “dBm”. Save all changes, back to a higher level menu. The computation method of the dBm: dBm = 10 x Log [(Reading ) / 0.001W ] 2-48 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Range of the dB setting value: -120 dBm ~ +120 dBm. The default is 0 dBm. NOTE: Input a value in dB setting interface by direction button, and then store it as dB setting value. Settings of dB value are stored in volatile memory. User’s Guide for DM3058/DM3058E 2-49 800.561.8187 information@itm.com www. .com...
Select Current, press On/Off to start REL operation, and then the readings in current set will be stored as a reference value. Users can input needed preset value by direction keys in the corresponding setting interface. 2-50 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Single Set Single manual trigger parameter. Set external triggering. Set the output signal pulse width at sampling ending output signal. Save all changes, back to a higher level menu. User’s Guide for DM3058/DM3058E 2-51 800.561.8187 information@itm.com www. .com...
The reading hold mode captures and holds a reading on the front panel display when a stable reading is detected. The system Hold ranges are 0.01%, 0.1%, 1%, and 10%. 2-52 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Page 72
The default value of hold range is 0.1%, and the range setting is stored in volatile memory. When Reading Hold started, the input resistance was set to 10MΩ for all DC voltage ranges to reduce noise arising from the open-loop testing. User’s Guide for DM3058/DM3058E 2-53 800.561.8187 information@itm.com www. .com...
Sample Count indicates the count of point sampled while the instrument getting a signal of Single Trigger. The range of sampling point should be between 1 and 2000. The default of Sample Count is 1. 2-54 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
In External Trigger Mode, the instrument could output a pulse signal through the six pin of RS232 interface on the rear panel after finishing sampling data. By the way, the polarity and output pulse width of this signal could be adjusted. User’s Guide for DM3058/DM3058E 2-55 800.561.8187 information@itm.com www.
Page 75
At external triggering mode, when P/F operating is ON, the instrument will export a pulse signal to indicate out of limitation. 2-56 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www.
Sensor Sensor Data Read Load the selected file. Save Save the file to the specified location. Erase Delete the selected file. Save all changes, back to a higher level menu. User’s Guide for DM3058/DM3058E 2-57 800.561.8187 information@itm.com www. .com...
Page 77
File1 to File10, then, press Read, Save and Erase buttons to do the corresponding operation. Press Save to enter the following interface. File Name Input Area Figure 2-75 Input File Name 2-58 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Page 78
Press A, a and 1 to select the Capital letter, Lowercase letter or Numbers. The Del function can only delete the letter on which the cursor taking place. Press Done to save current file. User’s Guide for DM3058/DM3058E 2-59 800.561.8187 information@itm.com...
To choose the commands To set up I/O and LAN parameters. System To set up system information configuration. Test and calibration function. Print Open/Close pint function. Save all the changes to end current operation 2-60 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
RIGOL Commands The multimeter is compatible with three types of commands which are RIGOL DM3058 commands, Agilent 34401A Commands and Fluke 45 Commands. RIGOL Commands is the default. Press Cmd to enter the following interface to choose needed Commands.
Remote control through GPIB (IEEE-488) , USB, RS-232 or LAN interface can be configured. Each time, only one of the GPIB, USB and RS-232 interfaces can be enabled. Note : only for DM3058. 2-62 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Page 82
Manual IP manually. Info View MAC address and other parameters. Apply Apply current LAN settings. Default Resume default settings. Set DNS server address. Save all changes, back to a higher level menu. User’s Guide for DM3058/DM3058E 2-63 800.561.8187 information@itm.com www. .com...
Page 83
You can set the address of multimeter to any integral value between 0 and 30. The default address is “7” when the instrument is shipped from the factory. Press I/O GPIB, enter the menu shown below: Figure 2-81 GPIB Setting 2-64 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Page 84
Proper configure the parity to make it same as that settled in your computer. There are three parameters: None, Odd, Even, the default is “None”. The current choice is stored in nonvolatile memory. User’s Guide for DM3058/DM3058E 2-65 800.561.8187 information@itm.com www.
Page 85
RIGOL NOTE: When RS-232 interface is used, the parity of multimeter: None parity: the digits sent by PC should be 8; Odd/Even parity: the digits sent by PC should be 7. 2-66 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Enable or Disable the front power switch. 1. Select languages The multimeter supports two kinds of languages for users. Press Sys Lang, enter the menu shown below: Figure 2-84 choose Language User’s Guide for DM3058/DM3058E 2-67 800.561.8187 information@itm.com www. .com...
Page 87
Sys Sound, enter the menu shown below. Turn on /Turn off the sound of button and information cue, the sound in short circuit measure can be closed. The current choice is saved in nonvolatile memory. Figure 2-86 Sound settings 2-68 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Page 88
Decimal and Separator cannot be selected as the same format, that is if the Decimal is “ ”, then the Separator can only be selected as “.”, “None” or “Space”. So there are six different types of way totally to show Number Format. User’s Guide for DM3058/DM3058E 2-69 800.561.8187 information@itm.com www.
Page 89
Filter DC Resistance 10MΩ Digit Resolution 5 ½ Measurement Function range Auto Math Function Factory Defaults Setting Math Stats Close Math Statistic Math Register All registers cleared * dBm Resistance *600Ω 2-70 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Page 90
NOTE*: Parameter with (*) are saved in non-volatile Reading Storage (3) Switch The front panel soft switch could be set to two working modes (enable or disable) to set whether the front panel power switch is valid at power-on. User’s Guide for DM3058/DM3058E 2-71 800.561.8187 information@itm.com www.
After input right password, Safety Lock will be open automatically. This instrument has been calibrated before leaving factory. To perform a calibration, please contact with the Technical Support Department of RIGOL for help. 2-72 User’s Guide for DM3058/DM3058E 800.561.8187...
RIGOL Print This function helps users to send out the measure values through RS-232 interface. Press print, enter the following interface: Figure 2-91 Print interface User’s Guide for DM3058/DM3058E 2-73 800.561.8187 information@itm.com www. .com...
Enter the next page help menu. Back to a higher level menu. NOTE: The arrowhead are hidden before any operation is token. The method of obtaining the help of the keyword: 2-74 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Page 94
Press and hold the key for more than 3 seconds at any operation interface to obtain Help information of the key. 9. To change the electric power fuse How to change the electric power fuse. 10. Support Getting the technique support. User’s Guide for DM3058/DM3058E 2-75 800.561.8187 information@itm.com www. .com...
Example 7: Reading Hold Example 8: Store and Recall the Preset Example 9: Mirror Image Configuration Example 10: To Realize Remote Control via LXI (only for DM3058) User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
As shown below, current Statistic State is “MAX” and current reading is the maximum of all. See the figures below, the maximum value will refresh with sample counts. Figure 3-1 Statistic Maximum User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Figure 3-4 Lead impedance after operation (4) Besides, The REL on the measurement interface could also open Relative operation. User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Select Reference resistance as measurement value (2) Press ON to turn on dBm measurement function. At this time, the reading shown on the screen is the Power value of reference resistance. Figure 3-6 Operation result User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www.
Figure 3-7 Set the set value of dB 5. Press ON to open dB measurement function. At this time, the reading shown on the screen is the Power difference between two circuits. Figure 3-8 Operation result User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Figure 3-10 Set the Low Limit Value (3) Press ON to start P/F tesing. As shown in Figure 3-11, The test result is “PASS” as the measured value is between 0V and 1V. Figure 3-11 P/F Test result User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www.
Figure 3-12 Sketch map for connecting Press New to enter into the setting interface. Figure 3-13 New interface Press Prpty to enter into the edit interface of Property. Figure 3-14 Edit interface User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Page 102
Figure 3-18 Edit interface of Reference value Press Add button, input the first group of reference value: 1V, 1℃. Figure 3-19 Input the first group of reference value Press Done to get a fist group of reference value. User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www.
Page 103
Figure 3-23 Finish interface 9. Press Save to load Sensor’s file has been saved to the Memory of DM3058/DM3058E. For the details please refer to Storage and Recall. Select Apply to load settings into current Sensor and use it directly.
Page 104
Figure 3-24 Apply interface 10. Press Disp and select Display mode of measurement result as All to view measurement value and its corresponding value. Figure 3-25 measure mode Figure 3-26 measure value 3-10 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
(2) Press to save all changes. (3) Repress to finish setting and close menu. 4. Press two times to start Hold function. 5. Connecting test leads into circuit and start measuring. User’s Guide for DM3058/DM3058E 3-11 800.561.8187 information@itm.com www. .com...
5. Save settings in step 3&4 to Set2 by using the method shown in step 2. Now the preset storage is finished. Press Set1 or Set2 to recall the settings when needed in later applications. 3-12 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
In virtue of this function, all the “System Configuration” and “Sensor Configuration” could by backup via USB flash device or clone to other DM3058/DM3058E. Up to 10 System Configuration files and 10 Sensor Configuration files could be stored in the instrument.
Page 108
5. At present, the m.mir file contains 2 system configuration files which are “Set1” and “Set2” and 2 sensor configuration files which are “a” and “b”. (1) You can delete the configuration files in DM3058/DM3058E and read (Read) the m.mir file again to re-release the files to the corresponding location inside DM3058/DM3058E.
Figure 3-35 Network setting interface Please input the IP address into the IE browser to open the main interface of the remote control system as shown in the figure on the next page. User’s Guide for DM3058/DM3058E 3-15 800.561.8187 information@itm.com www.
Page 110
Remote control system offers 6 kinds of operations to users. You can choose any one by the menus on left of main interface. Welcome page Network Status Network Settings Web Control Help Security Figure 3-37 Remote control system menus 3-16 User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Page 111
Choose “Web control”, and then an interface will pop up as follows. You can click the buttons to control instrument remotely. If you want to exit the system, please close the web, and press local button on instrument. Figure 3-38 Operation interface User’s Guide for DM3058/DM3058E 3-17 800.561.8187 information@itm.com www.
(3) Check if the safety fuse has been blown, replace with a new one if necessary. (4) Having done with the above steps, restart the instrument. (5) If it still cannot work properly, please contact the local RIGOL Support center, let’s serve for you.
Chapter 5 Measurement Tutorial True RMS AC Measurements The AC measurement of DM3058/DM3058E has true RMS response. The power dissipated in a resistor within a time is proportional to the square of the measured true RMS voltage, independent of wave shape. This multimeter can accurately measure true RMS voltage or current, as long as the wave shape contains negligible energy above the multimeter’s effective bandwidth.
Page 114
AC+DC true RMS value. You can determine this value by combining results from DC and AC measurements as shown below. You should perform the DC measurement using 5.5 digit mode for best AC rejection. User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www.
Generally speaking, the greater the crest factor, the greater the energy contained in high frequency harmonics. All multimeters have errors that are crest factor dependent. Crest factor errors for DM3058/DM3058E are listed in the AC Characteristics section in chapter 6. Please note that the crest factor errors do not apply for input signals below 100Hz.
RIGOL Loading Errors (AC Volts) In the AC Voltage function, the input of DM3058/DM3058E appears as a 1MΩ resistance in parallel with 100 pF of capacitance. The test lead that you use to connect signals to the multimeter will also add additional capacitance and loading.
RIGOL Application of the Analog Filter The analog filter of DM3058/DM3058E can be used to reduce the influence of the AC component in DC measurement. For most measurement, the filter may not require, but sometimes it can improve the DC measurement. For instance, if the DC electrical source to be measured has a big AC ripple, it can be reduced by the analog filter.
[6] Accuracy specifications are for the voltage measured at the input terminals only. 1 mA test current is typical. Variation in the current source will create some variation in the voltage drop across a diode junction. User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www.
Page 120
Continuity Threshold: Adjustable from 1Ω to 2000Ω Input Protection: 1000V Setting time attentions: Settling time in voltage measurement is affected by the source impedance, media characteristics of the cable and input signals. User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Page 122
Make sure the RC circuit of input terminal has been completely stable (up to 1s) before accurate measurement. Input >300Vrms (or >5Arms) will cause the self heating of the signal conditioning component to User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www.
Page 123
Internal temperature variation results from the self heating will cause additional error on ac range, this error is lower than 0.02% reading, and it will disappear after a few minutes. User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www.
Errors will occur when attempting to measure the frequency or period of an input following a dc offset voltage change. The input blocking RC time constant must be allowed to fully settle (up to 1 sec) before the most accurate measurements are possible. User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www.
Connection Type: 2-wire Input Protection: 1000V on all ranges Measurement attentions: Measurement of small capacitance is easily affected by external noise thus to cause measurement error, disable input will reduce this error. User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
Nonvolatile Memory: 10 groups history data storage (2000 readings/group) 10 groups sensor data storage (1000 readings/group) 10 groups instrument settings storage 10 groups sensor settings storage Support USB flash device external storage extend User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...
To avoid affecting the product performance, the length of USB Cable, LAN Cable and RS232 Cable connected to the instrument should be less than 3m. All the accessories are available by contacting your local RIGOL office. User’s Guide for DM3058/DM3058E 800.561.8187...
If a product proves defective within the respective period, RIGOL guarantees free replacement or repair of any defective products within a reasonable period of time. To get repair service, please contact with your nearest RIGOL sales or service office. There is no other warranty, expressed or implied, except such as is expressly set forth herein or other applicable warranty card.
Page 129
To avoid damage to the instrument, do not expose it to caustic liquids. WARNING To avoid short-circuit resulting from moisture or personal injuries, ensure that the instrument is completely dry before connecting it to the power supply. User’s Guide for DM3058/DM3058E 800.561.8187 information@itm.com www. .com...