Make Gas Connection - KitchenAid W10284348A Installation Instructions Manual

30" (76.2 cm), 36" (91.4 cm) and 48" (121.9 cm) commercial style dual fuel convection range
Table of Contents

Advertisement

Available languages

Available languages

3. Pull tube to ensure it is secured.
Sink
Water
supply
connection
Water supply tubing
to cold water supply
Shutoff
valve
4. Route flexible codes approved water supply line through
undersink cabinet and oven cabinet cutout.
5. Connect the flexible codes approved water supply line to the
range copper tubing, using a ¼" to ¼" water supply union.
B
C
A
A. To home water supply
B. Rear of cabinet cutout
C. Flexible codes approved water supply line from home
water supply
D. ¼" to ¼" water supply union (supplied in water filter kit)
E. Oven copper tubing
F. Range front
6. Turn on water supply.
7. Check all connections for leaks.
NOTE: No flushing or conditioning of the water filter is required
prior to use.
Water supply tubing to range
Yellow
WATER
IN
WATER
Filter
D
E

Make Gas Connection

Blue
Use a new CSA International approved gas supply line.
OUT
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
1. Assemble flexible connector from gas supply pipe to pressure
regulator located in the middle rear of the range.
F
2. Apply pipe-joint compound made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see B
and G in the following illustration).
3. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
4. Use a
" combination wrench and channel lock pliers to
attach the flexible connector to the adapters. Check that
connector is not kinked.
A
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter (must have ½" male
pipe thread)
D. Flexible connector
Complete Connection
1. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
WARNING
Explosion Hazard
B C
D
E
H
G
E. Manual gas shutoff valve
F. ½" or ¾" gas pipe
G. Use pipe-joint compound.
H. Adapter
A
B
A. Closed valve
B. Open valve
F