3-Wire Cable from Power Supply
IMPORTANT: Use the 3-wire cable from power supply where
local codes permit connecting the frame-ground conductor to
the neutral (white) junction box wire.
A
B
C
G
H
D
E
F
I
A. Cable from power supply
F. 4-wire cable from range
B. Junction box
G. Black wires
C. Red wires
H. UL listed wire nuts
D. White wire (from power supply)
I. UL listed or CSA approved
conduit connector
E. White and green (or bare) grounding
wires (from range) - factory crimped
1. Disconnect power.
2. Remove junction box cover if present.
3. Connect the flexible armored cable from the range to the
junction box using a UL listed or CSA approved conduit
connector.
4. Tighten screws on conduit connector if present.
5. Connect the two black wires together using UL listed wire
nuts.
6. Connect the two red wires together using UL listed wire nuts.
7. Connect the factory-crimped bare and white range cable
wires to the white (neutral) wire in the junction box using UL
listed wire nuts.
8. Install junction box cover.
9. Reconnect power.
Attach Backguard or Island Trim
WARNING
Excessive Weight Hazard
Use two or more people to move and install range.
Failure to do so can result in back or other injury.
1. Using 2 or more people, move range close to cabinet
opening.
2. Remove cardboard or hardboard from under range. Move
range into final position.
3. Attach the backguard or island trim as required for your
installation. See “Tools and Parts.” Attachment screws are
included in the literature package.