Oki Data CONFIDENTIAL
4.2.25 Plate Side R Assy
(1) Separate the Plate Side R Assy. (Refer to 4.2.23)
(2) Remove two (or three) screws (Silver)
(3) Remove two screws (Black)
(4) Remove four screws (Silver)
Gear-Idle-Z30-33
.
(5) Remove the screw (Silver)
(6) Remove two screws (Silver)
and Motor-Fan (40×15)
, Board-974
(7) Remove the screw (Silver)
(8) Installing is performed by the inverse procedure with removing.
Note!
1. Beware of not to touch the DC motor inattentively (Do not rotate motor).
2. Install Motor-FAN (40×15)
the appropriate projection of Guide-ID-R
3. While removing or installing FAN, do not press impeller of the FAN as shown by
the following photo. In case of the impeller unfastened by mistake, do not reuse it
and install a new FAN.
44871001TH Rev.6
. Remove the Guide-Cassette-R
. Remove the Connector
.
. Remove the Plate-ID-Gear
, Gear-Idle-Z21
. Remove the Holder-Switch
and Micro switch
, the screw (Black)
. Remove the Guide-ID-R
, Spring-ID Lock R
.
. Remove the Guide-Cable
.
with the label side inward and with its notch fitted to
.
.
,
.
Notch
Projection
View A
4.REPLACEMENT OF PARTS
View A
Impeller
4-52