Oki MB461 Maintenance Manual page 121

Hide thumbs Also See for MB461:
Table of Contents

Advertisement

Oki Data CONFIDENTIAL
(13) Remove two screws (Silver)
(14) Remove the screw (Silver)
(15) Remove the screw (Silver)
disconnecting every cable from it.
(16) Installing is performed by the inverse procedure with removing.
Note!
1. Fuser-Assy
may be really hot, beware of handling.
2. Beware of not to touch the DC motor inattentively (Do not rotate the motor).
3. Install the Fuser-Assy
carefully to avoid cables from being caught.
44871001TH Rev.6
. Remove the Plate-Duct-Assy
.
. Remove the Plate-Stacker-Lock
.
and screw (Black)
and lift off Fuser-Assy
(Reference)
The situation of the Mainbody
without the Plate Base (PWU).
after
Thick cable
Thin cable
View A
A hole to draw the thick cable
4.REPLACEMENT OF PARTS
View A
A hole to draw the thin cable
4-43