Oki Data CONFIDENTIAL
9.3.5 FW Update flow in case of Error 049
(for MB451, MB451w)
Step1
Connect the MFP and PC which is installed the Maintenance Utility (hereinafter
referred to as MU) via USB cable.
Step2
Push the power switch on the MFP , pressing simultaneously the "1" and "right(→)"
key of the operation panel.
Step3
Wait for about 1 minute untill the "Error 049" is displayed on the LCD, and press
simultaneously the "1" and "right(→)" key in the meantime.
Step4
Confirm the connection between the MFP and MU.
Step5
Send the indicated new FW Suite (CU version 01.28 or later) to the MFP .
Refer to the Maintenance Utility Operating Manual adout the method of sending.
Step6
Wait for 5 minutes from disappearance of "connecting" on status bar in the MU
main window.
Step7
Power off the MFP .
Step8
Same as step2.
Step9
Same as step3.
Step10
Same as step4.
Step11
Send the PJL (44946001FZ07) to the MFP .
Step12
Confirm that the response is "PASSED".
Refer to the Maintenance Utility Operating Manual adout the method of receiving
the response.
Step13
Same as step7.
Step14
Power on the MFP .
Step15
Confirm that the MFP is booting up normally.
Note! This FW update should be removed the TEL cable from the Scanner unit of the mainbody.