(5) Data frame error (Master transmission)
HITACH
Slave
(HV-F202SCL)
① Session starts when ENQ is sent from master to slave.
② Slave acknowledges by returning ACK to master.
③ Master sends data.
④ For some reason, slave does not receive data.
⑤ Master does not receive acknowledgment to the send data and repeats the sequence every 3
seconds for 3 times.
⑥ If unsuccessful after 3 attempts, master aborts the sequence and ends communication.
2
Send data (ASCII code)
4
Send data (ASCII code)
3CCD
Send data (ASCII code)
Send data (ASCII code)
ENQ code (05H)
ACK code (06H)
1
3
3 second
elapse
5
3 second
elapse
Master (Machine)
3 second
elapse
6
13