SYSTEM INITIALIZATION:

Maintenance and trouble-shooting procedures have been made easy and effective with
a built-in pressure gauge. It is recommended that you keep a replacement DI cartridge on
hand, ready to install as soon as the monitor indicates that the cartridge in use is exhausted
If you are setting up your system for the first time or replacing the membrane with
a different size, please follow the "Checking the concentrate to purified Water
Ratio" procedure on page 8 after you do the system hook-up below.
System Hook-Up
1. Attach the garden hose adapter (connected to the black tubing) to
your cold water source. Never run hot water (greater than 100° F
(38° C)) through the system.
2. Place the yellow concentrate (waste) tubing and the blue purified
(product) water tubing into a drain. Do not restrict flow from these
lines.
3. Open the cold water supply valve. You may use pressure up to 80 psi
(5.5 bar).
Check the system to ensure that all fittings are tight and leak- free
before leaving the system unattended. (If anything is leaking,
contact SpectraPure for assistance.)
Note: It is recommended that at least 2 gallons (7.57 liters) of purified
water be discarded now before collecting purified water for use. If the
unit is not used for several days, run the system for at least 10 minutes
before collecting any water. This will flush out any stale water in the
system.
4. Now follow procedure on page 8-12 to adjust the Flow Restrictor.
5. Finish the installation by connecting the yellow line to a drain. The
blue line can be placed into a Rubber Maid™ trash can or set up to
become automatic using a Liquid Level Controller (LLC-S-115 ),
(LLC-M-115) or the Auto Shut-Off Kit (ASOFK).
SpectraPure®Inc. assumes no responsibility for water damage due to leaks. It is
the user's responsibility to determine that the system is leak-free.
SpectraPure®Inc .
E-mail: spectra@spectrapure.com Visit us on the web www.spectrapure.com
®
Fax 480.894.6109 Fax us toll-free 1.877.527.7873