Troubleshooting The Ro Membrane - SpectraPure PROPLUS RO System Installation And Operating Manual

Reverse osmosis/ion exchange water purification system
Table of Contents

Advertisement

SpectraPure
TESTING THE QUALITY OF THE MEMBRANE:
Membrane Output Calculation
Membranes produce the rated gallons per day (GPD) at 60 psi (4.1 bars) operat-
ing pressure, 77°F (25°C) operating temperature and 500 ppm total dissolved
solids.
Membrane output gallons per day (GPD) depends on operating pressure, water
temperature and the ppm TDS in the feed water.
Expected GPD = Rated GPD × PCF × TCF
PCF is the pressure correction factor
TCF is the temperature correction factor
Calculation of Pressure Correction Factor (PCF):
the membrane is directly proportional to the applied pressure.
Note: The membrane is rated to produce the rated GPD at 60 psi. For any
pressure other than 60 psi the output GPD is multipled by the PCF.
PCF = Line Pressure (in psi) ÷ 60
Calculation of Temperature Correction Factor (TCF):
also decreases with decrease in temperature. This is because water viscosity
increases with decrease in water temperature.
Temperature Correction Factor Table (TCF)
°F /°C
TCF
41.0 /5
0.521
42.8 /6
0.540
44.6 /7
0.560
46.4 /8
0.578
48.2 /9
0.598
50.0 /10
0.620
51.8 /11
0.640
53.6 /12
0.661
55.4 /13
0.684
57.2/14
0.707
SpectraPure®Inc .
E-mail: spectra@spectrapure.com Visit us on the web www.spectrapure.com
®
°F \°C
TCF
59.0 /15
0.730
60.8 /16
0.754
62.6 /17
0.779
64.4 /18
0.804
66.2 /19
0.830
68.0 /20
0.857
69.8 /21
0.884
71.6 /22
0.912
73.4 /23
0.941
75.2 /24
0.970
Fax 480.894.6109 Fax us toll-free 1.877.527.7873
The output (GPD) from
The output (GPD)
°F \°C
TCF
77.0 /25
1.000
78.8 /26
1.031
80.6 /27
1.063
82.4 /28
1.094
84.2 /29
1.127
86.0 /30
1.161
87.8 /31
1.196
89.6 /32
1.232
91.4 /33
1.267
93.2 /34
1.304
19