Technical data
12.4
Extension cable
WARNING
Electrical voltage.
Injuries from electrocution.
Note:
42
Check power cable and extension cable for signs of damage.
Only use extension cables for which grounded conductors are connected to
the plug and the coupling (only for machines of class rating I, see chapter
Technical Data).
Only use permitted extension cables, see chapter Safety.
Refer to the following table for the required cross-section area of the exten-
sion cable:
Refer to the nameplate or the chapter Technical data (via the item
number) for the type designation and voltage rating of your machine.
Voltage
Extension
[V]
[m]
100 1~
< 17
< 29
< 46
< 68
115 1~
< 23
< 36
230 1~
< 56
< 92
< 147
120 1~
< 20
< 34
< 55
127 1~
< 24
< 40
< 64
Cross-section
area of cable
2
[mm
]
1.5
2.5
4
6
2.5
4
1.5
2.5
4
1.5
2.5
4.0
1.5
2.5
4.0
EH 23, 27