Advertisement

Quick Links

PORTABLE
GENERATORS
INSTALLATION AND
OPERATORS MANUAL
DL5000H/C
DL6000H/D
DL6000HE/E
WINCO INC.
225 S. CORDOVA AVE.
LE CENTER, MN 56057
507-357-6821
SERVICE DEPT.
507-357-6831
wincogen.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DL5000H/C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Winco DL5000H/C

  • Page 1 PORTABLE DL5000H/C GENERATORS DL6000H/D DL6000HE/E WINCO INC. 225 S. CORDOVA AVE. INSTALLATION AND LE CENTER, MN 56057 507-357-6821 OPERATORS MANUAL SERVICE DEPT. 507-357-6831 wincogen.com...
  • Page 2: Table Of Contents

    Should you experience a problem please follow the “Troubleshooting Tables” near the end of this MODEL ___________________________ manual. The warranty listed in the manual describes what you can expect from WINCO should you need SERIAL NUMBER_________________________ service assistance in the future. PURCHASE DATE_________________________ TABLE OF CONTENTS...
  • Page 3: Safety Information

    b. Keep fuel containers out of reach of children. SAFETY INFORMATION c. Do not smoke or use open fl ame near the generator set or fuel tank. This engine generator set has been designed and d. Keep a fi re extinguisher nearby and know its manufactured to allow safe, reliable performance.
  • Page 4: Unit Capabilities

    TESTING POLICY UNIT CAPABILITIES Before any generator is shipped from the factory, it GENERATOR CONNECTIONS is fully checked for performance. The generator is loaded to its full capacity, and the voltage, current DL6000H/DL6000HE - 120 volt and 240 volt re- and frequency are carefully checked.
  • Page 5: Preparing The Unit

    1. This generator-set was in good order when Most fractional horsepower motors take about the shipped. Inspect the generator-set promptly after same amount of current to run them whether they receiving it. If any damage is noted, notify the trans- are Repulsion Induction (RI), Capacitor (Cap), or portation company immediately;...
  • Page 6: Battery Installation

    the customer supplied battery on the unit. Use 4-stroke motor oil that meets or exceeds the requirements for If you intend to use the power plant’s electric start API service classification SJ or later (or equivalent). Always check system, you will need to purchase and install a bat- the API service label on the oil container to be sure it includes the letters SJ or later (or equivalent).
  • Page 7: Initial Start Up

    OIL ALERT SYSTEM This WINCO Industrial generator is equipped with a 2. Turn on the fuel supply by moving the fuel lever low oil shutdown system. This engine uses an fl oat to the “ON”...
  • Page 8: Electric Starting

    ENGINE SWITCH 4 Turn the off/on engine switch to the on position. 5. Pull the starter grip lightly until resistance is felt, CLOSED then pull briskly. 6. When the engine starts, open the choke ENGINE SWITCH OPEN OPEN gradually. 6. When the engine starts, release the engine 7.
  • Page 9: Operating Speed

    Although individual units and models vary slightly, Note: The use of a fuel additive, such a STA-BIL the normal voltage and frequency of the engine-gen- or equivalent will minimize the formation of gum erator described in this manual are approximately as deposits during storage.
  • Page 10: Wiring

    When installing the generator at these sites, a secondary emergency distribution panel may have to be installed, such as the Emergency Transfer/Ser- vice (ET/S) system available through your WINCO dealer. The emergency distribution panel must be installed by a licensed electrician according to all ap- plicable codes.
  • Page 11: Engine Care

    circuits to be powered during the outage to the emer- gency panel. Keep in mind only a limited amount of OIL FILLER CAP/ amperage is available from the generator set. Some DIPSTICK circuit breakers may still have to be turned off to prevent an overload on the generator during the initial WASHER start up.
  • Page 12: Generator Care

    has accumulated in the windings. If left, this mois- WARNING: EQUIPMENT DAMAGE ture can cause corrosion in the winding. Frequent operation of the engine generator set will also insure Never start or run the engine with the air fi lter re- that the set is operating properly should it be needed moved in an emergency.
  • Page 13: Troubleshooting

    TROUBLESHOOTING SPECIFICATIONS DL5000H/C Generator manufacturer WINCO Inc PROBLEM (SYMPTOMS) POSSIBLE Part number 15359-039 Rotor resistance 0.83 Ohms CAUSES Stator resistance G1-N. 0.64 Ohms ——————————————————————— Stator resistance G3-N 0.64 Ohms Won’t Start *Low Oil Level. Cap winding resistance 2.21 Ohms *Fouled spark plug.
  • Page 14: Wiring Diagrams

    WIRING DIAGRAMS 3072-10 60707-125...
  • Page 15: Month Limited Warranty

    To the extent permitted by law, any and all warranties, including those of merchantability and fi tness for a particular purpose, are limited to 24 months from date of purchase. In no event is WINCO liable for incidental or consequential damages.
  • Page 16: Warranty Statement

    WINCO cannot deny warranty solely for lack of receipts. As the generator owner, you should be aware that WINCO may deny you warranty coverage if your genera- tor or a part has failed due to abuse, neglect, or improper maintenance or unapproved modifi cations.