PORTABLE
GENERATORS
INSTALLATION AND
OPERATORS MANUAL
DL5000H/D
DL6000H/F
WINCO INC.
225 S. CORDOVA AVE.
LE CENTER, MN 56057
507-357-6821
SERVICE DEPT.
507-357-6831
wincogen.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Dyna DL5000H and is the answer not in the manual?

Questions and answers

Summary of Contents for Winco Dyna DL5000H

  • Page 1 PORTABLE DL5000H/D GENERATORS DL6000H/F WINCO INC. 225 S. CORDOVA AVE. INSTALLATION AND LE CENTER, MN 56057 507-357-6821 OPERATORS MANUAL SERVICE DEPT. 507-357-6831 wincogen.com...
  • Page 2: Table Of Contents

    Should you experience a problem please follow the “Troubleshooting Tables” near the end of this MODEL ___________________________ manual. The warranty listed in the manual describes what you can expect from WINCO should you need SERIAL NUMBER_________________________ service assistance in the future. PURCHASE DATE_________________________ TABLE OF CONTENTS...
  • Page 3: Safety Information

    b. Keep fuel containers out of reach of children. SAFETY INFORMATION c. Do not smoke or use open fl ame near the generator set or fuel tank. This engine generator set has been designed and d. Keep a fi re extinguisher nearby and know its manufactured to allow safe, reliable performance.
  • Page 4: Unit Capabilities

    TESTING POLICY UNIT CAPABILITIES Before any generator is shipped from the factory, it GENERATOR CONNECTIONS is fully checked for performance. The generator is loaded to its full capacity, and the voltage, current DL6000H - 120 volt and 240 volt receptacles are and frequency are carefully checked.
  • Page 5: Preparing The Unit

    1. This generator-set was in good order when Most fractional horsepower motors take about the shipped. Inspect the generator-set promptly after same amount of current to run them whether they receiving it. If any damage is noted, notify the trans- are Repulsion Induction (RI), Capacitor (Cap), or portation company immediately;...
  • Page 6: Battery Installation

    the customer supplied battery on the unit. Use 4-stroke motor oil that meets or exceeds the requirements for If you intend to use the power plant’s electric start API service classification SJ or later (or equivalent). Always check system, you will need to purchase and install a bat- the API service label on the oil container to be sure it includes the letters SJ or later (or equivalent).
  • Page 7: Initial Start Up

    OIL ALERT SYSTEM This WINCO generator is equipped with a low oil shutdown system. This engine uses an fl oat switch mounted inside the engine. If the oil level drops 2.
  • Page 8: Electric Starting

    ENGINE SWITCH 4 Turn the off/on engine switch to the on position. 5. Pull the starter grip lightly until resistance is felt, CLOSED then pull briskly. 6. When the engine starts, open the choke ENGINE SWITCH OPEN gradually. OPEN 7. Gradually move choke to the open position as 7.
  • Page 9: Operating Speed

    Add the fuel stabilizer to the fuel in the tank LOAD VS. OUTPUT and run the unit for 2 minutes to circulate the Generator Speed Frequency Voltage stabilizer throughout the fuel system. Load (RPM) (Hz) If you choose to remove the remaining fuel None 3690 61.5...
  • Page 10: Wiring

    Emergency Transfer/Service DO NOT OPERATE THIS GENERATOR INDOORS. (ET/S) system available through your WINCO dealer. The unit should be stored in a warm dry location. The emergency distribution panel must be installed...
  • Page 11: Engine Care

    ENGINE CARE OIL FILLER CAP/ If major engine service or repair is required, contact DIPSTICK an authorized engine service center. The manufac- turer of these engines has established an excellent WASHER world-wide engine service organization. Engine ser- vice is very likely available from a nearby authorized OIL LEVEL dealer or distributor.
  • Page 12: Generator Care

    4. Spark Plug: Replace annually or every 300 CLEANING hours of operation. Always replace with the same spark plug that came in the engine and check gap Remove dirt and debris with a cloth or brush. DO before installing. Spark plug gap is 0.030”. Poor NOT use high pressure spray to clean either the spark will also occur if spark plug wire does not fi...
  • Page 13: Troubleshooting

    TROUBLESHOOTING SPECIFICATIONS DL5000H/D Generator manufacturer WINCO Inc PROBLEM (SYMPTOMS) POSSIBLE Part number 15359-039 Rotor resistance 0.83 Ohms CAUSES Stator resistance G1-N. 0.64 Ohms ——————————————————————— Stator resistance G3-N 0.64 Ohms Won’t Start *Low Oil Level. Cap winding resistance 2.21 Ohms *Fouled spark plug.
  • Page 14 WIRING DIAGRAMS 3310-00 60707-126...
  • Page 15 To the extent permitted by law, any and all warranties, including those of merchantability and fi tness for a particular purpose, are limited to 24 months from date of purchase. In no event is WINCO liable for incidental or consequential damages.
  • Page 16 WINCO cannot deny warranty solely for lack of receipts. As the generator owner, you should be aware that WINCO may deny you warranty coverage if your genera- tor or a part has failed due to abuse, neglect, or improper maintenance or unapproved modifi cations.