Verifying That Data Can Be Passed Between Dbms; Connecting The Com Port To The Router - Zhone iMarc SLV 9126 Installation Instructions Manual

Table of Contents

Advertisement

Verifying That Data Can Be Passed
Between DBMs
Procedure
1
Select Test, then ISDN Call/PVC Tests
Main Menu → Test → ISDN Call/PVC Tests
2
Select the link to be tested.
3
Start a Test Call. The Status should be Active.
4
Wait as the originating DBM places the backup call.
The originating unit's Test LED is on.
If the Result is . . .
Frame Relay Link Up
Frame Relay Link
Suboptimal
Frame Relay Link Down
5
Select Stop to end the Test Call.
See Verifying Backup Setup in the iMarc SLV Configuration Reference for additional
information.

Connecting the COM Port to the Router

If the Modem PassThru feature will be used, the terminal or PC must be disconnected and the
COM port connected to the router's AUX port. A standard cable can be used. See Connectors,
Cables, and Pin Assignments in the iMarc SLV Technical Description for additional information.
30
Then . . .
The call was successful.
Not all links have come up. Verify that the Maximum Link
Rate (Kbps) setting in the ISDN Link Profile is the same at
both ends.
The call was unsuccessful. Verify the configuration and
Link Status in the ISDN Link Profile.
9126-A2-ZN11-40