Reset Bmc Passwords; Configure Serial Port Parameters - HP Integrity rx4640 Operation And Maintenance Manual

Hide thumbs Also See for Integrity rx4640:
Table of Contents

Advertisement

Table 5-3
Management Processor Commands and Descriptions (Continued)
Command
SO
Security options
SS
System processor status
SYSREV
Current system firmware revisions
TC
Reset via transfer of control (TOC)
TE
Tell- send a message to other users
UC
User configuration
VFP
Virtual front panel
WHO
Display connected management processor users
X
Exit management processor and disconnect
XD
Diagnostics and/or reset of management processor

Reset BMC Passwords

BP: Reset BMC Passwords
This command resets BMC passwords (both USER and ADMIN passwords).

Configure Serial Port Parameters

CA: Configure local and remote serial port parameters
Set up the local serial port parameters as follows:
TERMINAL TYPE: Vt100 vs HPterm
BAUD RATES: Input and output data rates are the same; 300, 1200, 2400, 4800, 9600, 38400, 115200 bit/sec.
FLOW CONTROL: Hardware uses RTS/CTS; Software uses Xon/Xoff.
TRANSMIT CONFIGURATION STRINGS: Disable this setting whenever the modem being used is not compatible with
the supported modem (MT5634ZBA).
IMPORTANT Do not mix HP and vt100 terminal types at the same time.
Set up the remote serial port parameters as follows:
MODEM PROTOCOL: Bell or CCITT (CCITT is a European standard; RTS/CTS signaling is used, as well as the Ring
signal. Bell is a U.S. or simple mode).
BAUD RATES: Input and output data rates are the same; 300, 1200, 2400, 4800, 9600, 38400, 115200 bit/sec.
FLOW CONTROL: Hardware uses RTS/CTS; Software uses Xon/Xoff.
TRANSMIT CONFIGURATION STRINGS: Disable this setting whenever the modem being used is not compatible with
the supported modem (MT5634ZBA).
MODEM PRESENCE: When the modem may not always be connected, set this parameter to "not always connected".
Chapter 5
Management Processor Command Interface
Description
Utilities
111

Advertisement

Table of Contents
loading