Pump Location

NOTE: In Canada, the pump must be located a minimum of three (3) meters (approximately ten
(10) feet) from the water (CSA C22.1).
1. Speck Pumps recommends in order to achieve better self-priming, to install the pump as close to the
pool as practical. Consult local codes for minimum distance between pool and pump.
WARNING: Some Safety Vacuum Release System (SVRS) devices are not compatible with
the installation of check valves. If the pool has an SVRS device, be sure to confirm that it will
continue to safely operate when the check valves are installed.
2. The piping should be as direct and free from turns or bends as possible, as elbows and others fittings
greatly increase friction losses.
3. Place pump on solid foundation which provides a rigid and vibration-free support so that it is readily
accessible for service and maintenance.
4. Protect the pump against flooding and excess moisture, and prevent foreign objects from clogging
air circulation around motor. All motors generate heat that must be removed by providing proper
ventilation.
5. DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this pump. DO
NOT store pool chemicals near the pump.
6. DO NOT remove any safety alert labels such as DANGER, WARNING, or CAUTION. Keep safety
labels in good condition and replace any missing or damaged labels.
7. Provide access for future services by leaving a clear area around the pump. Allow plenty of space
above the pump to remove lid and basket for cleaning.
8. Install the pump in a well ventilated location protected from direct sunlight and excessive moisture.
(rain, sprinklers, etc.)

Pipe Sizing

NOTE: All pipe sizes are able to withstand the pressures the pump will deliver, but not
necessarily the flow. If the pipe is too small for the pump, or is elevated above water, the
maximum gallons per minute (GPM) may not be delivered. If this happens, the pump will
develop a pocket of air (cavitation) that makes noise. This may shorten the life of the pump.
SUCTION & DISCHARGE:
When the pump is located up to 50 feet from the pool, the recommended minimum pipe size for both
the suction and discharge is 2".

Plumbing Installation

When installing the pump, care should be taken to see the suction line is below water level to a point
immediately beneath the pump to ensure quick priming via a flooded suction line. The height between
the pump and water level should not be more than five (5) feet.