Speck pumps ES90 Owner's Manual

Swimming pool and spa pump

Advertisement

OWNER'S MANUAL
Swimming Pool and Spa Pump
Notice:
The California Energy Commission requires all pumps purchased for sale or use in a residential pool for filtration
in California be listed on their CEC website.
Important Notice:
use of this product. This information should be given to the owner and/or operator of this equipment.
WARNING: This product must be installed and serviced by a qualified pool professional, and must conform to all
national, state, and local codes.
WARNING: Before installing this product, read and follow all warning notices and instructions which are included.
Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call
(800) 223-8538 or visit www.usa.speck-pumps.com for additional copies of these instructions.
IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment,
basic safety precautions should always be followed,
including the following:
READ AND FOLLOW ALL
1.
INSTRUCTIONS.
2. WARNING - To reduce the risk of injury, do not
permit children to use this product unless they are
closely supervised at all times.
3. WARNING - Risk of Electrical Shock. Connect only
to a branch circuit protected by a ground-fault circuit
interrupter (GFCI). Contact a qualified electrician if you
cannot verify that a circuit is protected by a GFCI.
4. WARNING - To reduce the risk of electric shock,
replace any damaged cord immediately.
5. DO NOT install within an outer enclosure or beneath
the skirt of a hot tub or spa.
6. CAUTION - This pump is for use with permanently-
installed pools and may also be used with hot tubs and
spas if so marked. Do not use with storable pools. A
permanently-installed pool is constructed in or on the
ground or in a building such that it cannot be readily
disassembled for storage. A storable pool is constructed
so that it is capable of being readily disassembled for
storage and reassembled to its original integrity.
READ THIS MANUAL CAREFULLY
BEFORE USING THE SPECK PUMP
This manual contains important information about the installation, operation and safe
7. The unit must be connected only to a supply circuit
that is protected by a ground-fault circuit-interrupter
(GFCI). Such a GFCI should be provided by the installer
and should be tested on a routine basis. To test the
GFCI, push the test button. The GFCI should interrupt
power. Push the reset button. Power should be
restored. If the GFCI fails to operate in this manner,
the GFCI is defective. If the GFCI interrupts power to
the pump without the test button being pushed, a
ground current is flowing, indicating the possibility of
an electric shock. Do not use this pump. Disconnect the
pump and have the problem corrected by a qualified
service representative before using.
8. TO REDUCE RISK OF ELECTRICAL SHOCK, A copper
bonding connector (8 AWG U.S., 6 AWG Canada) is
provided for bonding the motor to all metal parts of
the swimming pool, spa, or hot tub structure and to all
electrical equipment, metal conduit, and metal piping
within 5 feet of the inside walls of a swimming pool,
spa, or hot tub, when the motor is installed within 5
feet of the inside walls of the swimming pool, spa, or
hot tub.
NOTE: To installer and/or operator of the Speck
Swimming Pool Pump; the manufacturer's warranty
will be voided if the pump is improperly installed and/
or operated.
SAVE THESE
9.
INSTRUCTIONS!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ES90 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Speck pumps ES90

  • Page 1 OWNER’S MANUAL Swimming Pool and Spa Pump READ THIS MANUAL CAREFULLY BEFORE USING THE SPECK PUMP Notice: The California Energy Commission requires all pumps purchased for sale or use in a residential pool for filtration in California be listed on their CEC website. Important Notice: This manual contains important information about the installation, operation and safe use of this product.
  • Page 2: Section 1 Equipment Operation And Maintenance

    SECTION 1 EQUIPMENT OPERATION AND MAINTENANCE 1/1 LOCATION 5. Before starting the pump for the first time, remove the see-through lid. (Turn lid ring counterclockwise to remove.) 1. Locate the pump as close to the pool as practical. Consult Fill strainer tank with water until it is level with the suction local codes for minimum distance between pool and pump.
  • Page 3: Section 2 Troubleshooting Guide

    Check that all power switches are on. Be sure fuse or circuit breaker is properly set. Time set properly? Check motor wiring at terminals. b. Pump jammed. With power off, turn shaft. It should spin freely. If not, disassemble and repair. 2999999928A - Rev. 0520 - Model A91 & ES90...
  • Page 4: Section 3 Servicing Information

    Replacement parts may be available from your installer. When calling the manufacturer regarding a question or Call, fax, or write: Speck Pumps at 8125 Bayberry Road, problem with your pump, please have the serial number available. The serial number is located on the pump either Jacksonville, Florida 32256 Phone (904) 739-2626 Fax on the flange or motor labels.
  • Page 5: Section 4 Parts And Exploded View

    98/6.5mm IMPELLER (-II) 1.0 THP (1.5 HP SPL) 98/9mm MECHANICAL SEAL (5/8”) - CARBON/CERAMIC SCREW - CASING HEX/WASHER/SLOT M7x48.4mm 412.2 O-RING - CASING 165 x 6mm FLANGE/SEAL HOUSING 894.1 LEGO (FOOT) 2999999928A - Rev. 0520 - Model A91 & ES90...
  • Page 6: Section 5 Product Registration

    2. To the fullest extent permitted by law, the Limited Warranty will be void and of no force or effect and Speck Pumps-Pool Products, Inc. will have no liability, responsibilities or obligations to Buyer or with respect to the pump and motor in the event of the occurrence of any one or more of the following:...
  • Page 7 8125 Bayberry Road, Jacksonville, Florida 32256. Under no condition will products be accepted after the expiration of the Limited Warranty Period. Speck Pumps-Pool Products, Inc. shall not bear any costs or risks incurred by Buyer in shipping a defective pump and motor to Speck Pumps- Pool Products, Inc.
  • Page 8: Before Using The Pump

    Always disconnect power to the pool pump at the circuit breaker before servicing the pump. Failure to do so could result in death or serious injury to serviceman, pool users, or others due to electric shock. SAVE THESE INSTRUCTIONS! 2999999928A - Rev. 0520 - Model A91 & ES90 500.EB.JP...

This manual is also suitable for:

A91A91-ii cspA91-i ssp

Table of Contents