Adjusting The Speed - Speck pumps Badu EcoM3V Installation, Operating And Service Manual

Variable speed pool pump
Table of Contents

Advertisement

Changing the Default Speed - continued
5. The low speed LED will continue to blink for three seconds to indicate a modification to the automatic
default speed is being requested. After a brief pause, a second series of LED blinks will indicate the new
default setting has been set to either medium speed (medium speed LED blinks) or low speed (low speed
LED blinks).
Adjusting the Speeds
The Badu EcoM3 - Variable Speed pump control panel provides manual speed controls for the pump.
There are three (3) factory preset buttons that can be selected (LOW, MED, or HIGH). The LOW button
is preset to 1600 RPM. The MED button is preset to 2600 RPM. The HIGH button is preset to 3450
RPM. Once a button (LOW, MED, or HIGH) is pressed the LED for the appropriate button will appear.
However, the three (3) speeds can be modified to various speeds required by minimum flow pressure
requirements of various pool side equipment/features as defined by the manufacturer specifications.
Please follow all local/state regulations regarding pool motor and timer speeds settings when
choosing the appropriate speeds.
To Adjust LOW Speed
Verify that the pump is powered ON and the green power LED light is on.
Press the LOW button for 5 to 10 seconds, this will switch the control from Normal Operation Mode
to the Speed Adjust Mode. The LOW LED light will begin to blink.
Press the left (LOW) button to decrease the speed.
or
Press the right (HIGH) button to increase the speed.
(NOTE: The button will increase or decrease in increments of 200 RPM, in most cases. The
Speed Range for Low Speed is 1000, 1200, 1400, 1600, 1725. Factory Preset is 1600.)
Press the middle (MED) button to save the current the speed and return to Normal Operation Mode.
To Stop or Exit out of Speed Adjust Mode, Press the STOP button or wait 30 seconds without pressing
any buttons. NOTE: If the power is shut off or the pump is stopped using the stop button, upon
powering up the pump will run a two (2) minute prime on HIGH and then resume normal operation.
DO NOT press any buttons during prime operation.
To Adjust the MEDIUM Speed
Verify that the pump is powered ON and the green power LED light is on.
Press the MED button for 5 to 10 seconds, this will switch the control from Normal Operation Mode to
the Speed Adjust Mode. The MED LED light will begin to blink.
Press the left (LOW) button to decrease the speed.
or
Press the right (HIGH) button to increase the speed.
(NOTE: The button will increase or decrease in increments of 200 RPM, in most cases. The Speed
Range for Medium Speed is 1800, 2000, 2200, 2400, 2600, 2800. Factory Preset is 2600.)
Press the middle (MED) button to save the current the speed and return to Normal Operation Mode.
To Stop or Exit out of Speed Adjust Mode, Press the STOP button or wait 30 seconds without pressing
any buttons. NOTE: If the power is shut off or the pump is stopped using the stop button, upon
powering up the pump will run a two (2) minute prime on HIGH and then resume normal operation.
DO NOT press any buttons during prime operation.
14