Important Safety Instructions - Speck pumps Badu EcoM3V Installation, Operating And Service Manual

Variable speed pool pump
Table of Contents

Advertisement

1

Important Safety Instructions

READ THIS MANUAL CAREFULLY BEFORE USING THE SPECK PUMP
Important Notice:
This manual contains important information about the installation, operation and safe use of this product.
This information should be given to the owner and/or operator of this equipment.
WARNING: Before Installing this product, read and follow all warning notices and instructions which
are included. Failure to follow safety warnings and instructions can result in severe injury, death, or
property damage. Call 1-800-223-8538 or visit www.usa.speck-pumps.com for additional copies of these
instructions.
WARNING - Entrapment Prevention
4
READ AND FOLLOW ALL INSTRUCTIONS!
DANGER: DO NOT BLOCK SUCTION
SUCTION HAZARD. Can cause serious injury or death. Do not use
this pump for wading pools, shallow pools, or spas containing bottom
drains, unless pump is connected to at least two (2) functioning suction
outlets.
WARNING: Pump suction is hazardous and can trap and drown or
disembowel bathers. Do not use or operate swimming pools, spas, or
hot tubs if a suction outlet cover is missing, broken, or loose.
The following guidelines provide information for pump installation
that minimizes risk of injury to users of pools, spas, and hot tubs:
Entrapment Protection: The pump suction system must provide
protection against the hazards of suction entrapment.
Suction Outlet Covers: All suction outlets must have correctly installed,
screw-fastened covers in place. All suction outlet (drain) covers must be
maintained. Drain covers must be listed/certified to the latest published
edition of ANSI/ASME A112.19.8 (ANSI/APSP-16, 2011). They must be
replaced if cracked, broken, or missing.
Number of Suction Outlets Per Pump: Provide at least two (2)
hydraulically-balanced main drains, with covers, as suction for each
circulating pump suction line. The centers of the main drains (suction
outlets) on any one (1) suction line must be at least three (3) feet apart,
center to center.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents