Voltage Checks; Pressure Testing - Speck pumps Badu EcoM3V Installation, Operating And Service Manual

Variable speed pool pump
Table of Contents

Advertisement

Electrical Installation - continued
Org
L 1
Wht
L 2
Green/
Ground
Yellow
Red
White
Yellow
Connection
Control Box
Top Half

Voltage Checks

The correct voltage, as specified on the pump data plate, is necessary for proper performance and long
motor life. Incorrect voltage will cause the error light to turn on and cause damage to the motor if not
turned off immediately.
It is the responsibility of the electrical installer to provide data plate operating voltage to the pump by
ensuring proper circuit sizes and wire sizes for this specific application.
CAUTION: Failure to provide data plate voltage during operation will cause the motor to
overheat and void the warranty.
Pressure Test
WARNING: When pressure testing a system with water, air is often trapped in the system during
the filling process. This air will compress when the system is pressurized. Should the system
fail, this trapped air can propel debris at a high speed and cause injury. Every effort to remove
trapped air must be taken, including opening the bleed valve on the filter and loosening the
pump basket lid while filling the pump.
WARNING: Trapped air in the system can cause the filter lid to be blown off, which can result in
death, serious injury, or property damage. Be sure all air is properly purged out of the system
before operating. DO NOT USE COMPRESSED AIR TO PRESSURE TEST OR CHECK FOR
LEAKS.
Green\Yellow
White
Orange
Connection
Control Box
Lower Half
Figure 2
Red
White
Yellow
11

Hide quick links:

Advertisement

Table of Contents