Install Cooktop

WARNING
Excessive Weight Hazard
Use two or more people to move and install cooktop.
Failure to do so can result in back or other injury.
Write down the model and serial numbers before installing the
cooktop. Both numbers are located on the left front underside of
the cooktop base.
Unpack the parts supplied with your cooktop. The parts shipped
with the cooktop depend on your model ordered. See "Tools and
Parts" section for a complete list parts supplied with your
cooktop.
The pressure regulator and flexible stainless steel gas supply line
connector can be assembled to the cooktop now or after the
cooktop is installed in the cutout. See "Make Gas Connection"
section.
1. Decide on the final location for the cooktop.
2. Using two or more people, place the cooktop upside down
on a covered surface.
3. Remove foam strip from literature packing. Remove backing
from foam strip. Apply foam strip adhesive-side down along
the left and right sides of the cooktop trim.
NOTE: The foam strip helps the cooktop sit flat on uneven
counters and avoids damage to the countertop surface.
A. Cooktop base
B. Foam strip
C. Cooktop
4. Using 2 or more people, turn cooktop right side up.

INSTALLATION INSTRUCTIONS

A
B
C

Install Optional Backguard

48" (121.9 cm) models and all models with a grill may require a
backguard. See "Cabinet Dimensions" in the "Location
Requirements" section for installation requirements. See the
"Tools and Parts" section for information on ordering.
Remove island trim and attach backguard using 6 screws, insert
3 from the front and 3 from the back (9" [22.9 cm] backguard
shown).

Make Gas Connection

WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
To Assemble Pressure Regulator:
1. Using 2 or more people, stand the cooktop on its side or
back.