Set Elapsed Time In Minutes Since Last Autotest - GE NX-148E Installation And Setup

Networx series nx-148e lcd keypad installation and setup
Hide thumbs Also See for NX-148E:
Table of Contents

Advertisement

DISPLAY
Open
Close
Exit Err
Rec Close
Autotest
Start Prog
End Prog
Start Dnld
End Dnld
Cancel
Gnd Flt
Man Test
Re-exit
Output Trip
Data Lost
Walk-test
End Test
Cross-Trip
Expansion
Event
Partial Arm
Listen In
Service Start
Service End
Code Entry
First Open
Last Close
Sprnklr
Clock Set
RF Jammed
CleanMe
7b. SET ELAPSED TIME IN MINUTES SINCE LAST AUTOTEST
ACTION
[program code]
(example only)
#
LCD KEYPAD
Open - Reports user number, date, time and partition of opening.
Close - Reports user number, date, time and partition of closing.
Exit Error - Entry/Exit zone was faulted at the instant the exit delay expired.
Recent Close - An alarm occurred within 5 minutes after the control was armed.
Auto Test - Sending a communicator test at a specified interval.
Start Programming - Local programming is started.
End Programming - Local programming is ended.
Start Download - Download session is started.
End Download - Download session is ended.
Cancel - System is disarmed; Cancel was initiated within 5 minutes of an alarm.
Ground Fault - A short to ground has been detected.
Manual Test - Bell and/or communicator test while system is in disarmed condition.
Re-Exit - The exit delay has been re-started without disarming the system.
Output Trip - A trip has occurred on an expander auxiliary output.
Data Lost - Communication of a signal has failed (log only event).
Walk-Test - A zone "Walk-Test" mode has been activated.
End Test - Test has been ended.
Cross Trip - The first zone of a cross zone has been tripped (log only event).
Expansion Event - An expansion module has created an undefined event.
Partial Arm - Reports a closing in the stay mode.
Listen In - A listen in function has been activated.
Service Start - Technician is on site.
Service End - Technician is off site.
Code Entry - A code has been entered.
First Open - Reports when the first partition is disarmed.
Last Close - Reports when the last partition is armed.
Sprinkler - Instant sprinkler supervisory report
Clock Set - Clock has been reset.
RF Jammed - A wireless expansion module is jammed
CleanMe - A smoke detector requires cleaning.
DESCRIPTION
Prompts for a code.
Displays the elapsed time screen.
[100's digit] [10's digit] [1's digit]
Saves and exits.
RESULT
13