SERVICE INSTRUCTIONS - (DO NOT MODIFY THIS APPLIANCE)
General
1. Service work to be carried out by an authorised service person only.
2. Unplug from wall socket or turn off power at main switchboard if heater
is hard wired.
3. Always shut off the gas supply and ensure that the heater is cool before
commencing any service operations.
4. Always check for gas soundness after servicing.
To replace the primary glass
1. Refer pages 13 and 14, steps 7 to 11, of the installation instructions.
Refit glass and replace in reverse order ensure the inside surface of the
glass is clean and free from finger marks.
Note: ensure the inside surface of the glass is clean and free from finger
marks.
To replace the gas control
1. Remove the fascia
2. Unplug the cables from the gas control and disconnect the earth
connection.
3. Disconnect the gas inlet (1/2" compression nut) connection at entry
gas control and the 16mm nut at the outlet of the gas control.
4 . Remove the three M4 screws from the cradle retaining the gas control.
5. Remove gas control.
6 Replace gas control in reverse order and check for gas tightness
Note: check the gas pressure on high and low burner settings. Refer 'gas
control', pages 13 and 14
Ignition module
Mounting bracket
To replace the ignition (module) device
1. Unplug wire connectors from ignition module.
2. Remove module mounting bracket by removing
mounting screw.
3. Using pliers bend tabs so that module can come
away from the mounting bracket.
4. Replace ignition device in reverse order.
22

REGULATORY LOCATION

FIG 2. MINIMUM CLEARANCES REQUIRED FOR BALANCED FLUE
TERMINALS, FAN ASSISTED FLUE TERMINALS, ROOM SEALED APPLIANCE
TERMINALS OR THE TERMINALS OF OUTDOOR APPLIANCES.
T = Flue terminal
I = Mechanical air inlet
Ref
a
b
c
d
e
f
g
h
j
k
n
FIG 29.
Special Note:
This chart shall be read in-conjunction with the full Australian standards.
AS 5601
j
T
h
j
j
Openable
window
h
n
F
h
Door
k
T
I
k
g
M = Gas meter
P = Electricity meter or fuse box
Item
Below eaves, balconies and other projections:
Appliances up to 50 MJ/hr input
Appliances over 50 MJ/hr input
From the ground, above a balcony or other surface
From a return wall or external corner
From a gas meter (M) (see 4.7.11 for vent location of regulator)
From electricity meter or fuse box (P)
From a drain pipe or soil pipe
Horizontally from any building structure or obstruction facing a terminal
From any other flue terminal, cowl, or combustion air intake
Horizontally from an openable window, door, non-mechanical air inlet or other opening into a
building with the exception of sub-floor ventilation:
Appliances up t 150 MJ/hr input
Appliances over 150 MJ/hr input up to 200 MJ/hr input
Appliances over 200 MJ/hr input
All fan assisted flue appliances, in the direction of discharge
From a mechanical air inlet, including a spa blower
Vertically below an openable window, non-mechanical air inlet, or any other opening into a building
with the exception of sub-floor ventilation:
Space heaters up to 50 MJ/hr input
Other appliances up to 50 MJ/hr
Appliances over 50 MJ/hr input and up to 150 MJ/hr input
Appliances over 150 MJ/hr
- unless appliance is certified for closer installation
Notes:
1 All distances are measured to the nearest part of the terminal.
2 Prohibited area below electricity meter or fuse box extends to ground level.
3 See clause 5.13.6.6 for restrictions on the flue terminal under covered areas.
4 See Appendix J. Figures J2(a) and J3(a), for clearances required from a flue terminal to an LP
Gas Cylinder. A flue terminal is considered to be a source of ignition.
5 For appliances not addressed above acceptance should be obtained from the technical regulator.
THE POWER FLUE HEATER IS FAN ASSISTED. SEE COLUMN HIGHLIGHTED
a
c
e
e
See note 3
d
g
P
M
d
T
b
See note 2
Shading indicates prohibited
areas for flue terminals
Minimum clearances
(mm)
Fan
Natural
draft
assisted
300
200
500
300
300
300
500
500
1000
1000
500
500
150
75
500
500
500
500
500
300
1500
1500
1500
1500
1500
1500
1500
150
150
500
500
1000
1000
1500
1500
7