Electrical Requirements - KitchenAid Pro Line FRONT-LOADING GAS DRYER Use And Care Manual

Kitchenaid pro linetm front-loading gas dryer use&careguide
Table of Contents

Advertisement

Available languages

Available languages

Recommended installation spacing for recessed or
closet installation, with or without a pedestal
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
1"
27"
1"
1"
(2.5 cm)
(68.6 cm)
(2.5 cm)
(2.5 cm)
A
A. Front view
B. Side view - closet or confined area
C. Closet door with vents
*Required spacing
Recommended installation spacing for cabinet
installation, with or without a pedestal
For cabinet installation, with a door, minimum ventilation
openings in the top of the cabinet are required.
7"* (17.8 cm)
1"
27"
1"
5"
(2.5 cm)
(68.6 cm)
(2.5 cm)
(12.7 cm)
A
A. Front view
B. Side view
C. Cabinet with vents
*Required spacing
Mobile home - Additional installation requirements
This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280) or Standard
CAN/CSA-Z240 MH.
2
48 in.
*
2
(310 cm
)
2
24 in.
*
2
(155 cm
)
33"
5"
(83.8 cm)
(12.7 cm)
B
C
7"* (17.8 cm)
1"
33"
(88.8 cm)
(2.5 cm)
B
C
Mobile home installations require:
Metal exhaust system hardware, which is available for
purchase from your dealer.
Mobile home Installation Kit Part Number 346764. See "Tools
and Parts" section for ordering information.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
3"*
exhaust opening.
(7.6 cm)

Electrical Requirements

3"*
(7.6 cm)
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
120 Volt, 60 Hz., AC only, 15- or 20-amp fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. It is also recommended that a separate circuit
serving only this dryer be provided.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with the
dryer: if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
SAVE THESE INSTRUCTIONS