11. [DC685-4] Rotate the Screw with the Adjustment screw as required. (Fig. 5)
The UI indicates the rotation amount and direction of the LSU (ROS) skew adjustment
screw. The number indicates the rotation amount, + meaning to turn the screw clockwise,
and - meaning to turn it counter--clockwise.
For adjustment amount, one click of the adjustment screw (rotate it until it makes a click
sound) is equivalent to 0.05 in number. One rotation is equivalent to 20 clicks.
When the number that cannot be divided by 0.05 is displayed, round it up to 0.05 to reduce
the variation, and rotate it for as many times as the numbers rounded up.
E.g.
When 1.08, 1.09, 1.11, 1.12: make 22 clicks as they are rounded up to 1.10.
When 1.13, 1.14, 1.16, 1.17: make 23 clicks as they are rounded up to 1.15.
(1) Open the Front Cover and remove the collection bottle.
(2) Adjust the adjustment amount read from the UI display with the adjustment screw.
(3) Return the collection bottle and cheat the Interlock.
(Fig. 5) j0mf40951
12. [DC685-4]: After adjustment, return to DC685 -1: Skew Fine SetUP and repeat the steps.
2-13

ADJ1. 1. 7 DC945 IIT Calibration

Purpose To calculate and set up the White Reference Correction Coefficient. To correct the IIT
sensitivity dispersion.
Obtain the light axis correction data when replacing the lens unit, and adjust it.
Function details
Reference Refer to Chapter 3, 3. 4. 4. 24 DC945 IIT Calibration for details on how to use the
DC945 Diag.
The P-paper is the standard paper used in this procedure.If you have adjusted this proce-
dure by using following papers, need to change NVM (715-144) data.
715-144 (Default is 0.:P-Paper)
0:P-paper
1:J-paper
2:Digital Color Expression
3:4200 paper
4:Color Tech+
5:Xerox Business
Adjustment
Procedure
1. Enter DC945.
The following measurement items can be selected in the Execution column.
White Reference Adjustment
CCD Calibration
Light Axis Fluctuation Correction
<White Reference Adjustment>
(1) Select and execute the White Reference in the Execution column.
(2) Follow the instructions on the screen. (Paper to load on the platen: 10 sheets or more
of Plain paper)