2.2 SERIES OPERATION

• Up to 2 units with the same rating (voltage and current) can be used in series to increase the output voltage.
• Connect Main Outputs in series (as shown).
• Diodes should be connected in parallel with each unit output to prevent reverse voltage. Each diode should be rated to at least
the power supply rated output voltage and output current.
• Connect as shown : +Sense of positive unit and –Sense of negative unit (twisted pair) to Load point, or to +V and –V accordingly
for Local Sense.
• In case PMBus is used Connect PMBus signals in parallel (PMBus is isolated from Output), and choose different Address for each
unit (see chapter 3).
• Output Voltage can be adjusted independently for each unit.
• Controls Monitoring signals and +12V AUX are referenced to "SIGNAL RETURN" and may be connected in parallel.
Fig 2.2 HFE2500 series connection (remote sense configuration)
*
Diodes rated to at least Vout max and lout max