Series Operation - TDK-Lambda ZWS300RC Series Instruction Manual

Table of Contents

Advertisement

6-6. Output Ripple & Noise
The specified maximum ripple & noise value is measured according to below measurement circuit. When load
lines are longer, ripple will becomes larger. In this case, electrolytic capacitor, film
capacitor, etc. might be necessary to be used across the load terminal.
The output ripple cannot be measured accurately if the probe ground lead of oscilloscope is too long.
150mm
+V
Power
C1
Supply
-V
6-7. Series Operation  
For series operation, either method (A) or (B) is possible.
Never use when one of the unit not operate, which leads damage.
In series operation, the rising waveform may have steps.
(A)
+V
Power
Supply
-V
+V
Power
Supply
-V
A
C1 : 0.1uF
C2 : 100uF
+
Load
C2
C3 : 4700 pF Ceramic Cap.
R1 : 50 Ω
Coaxial Cable
1.5 m 50 Ω
(B)
Power
Supply
+
load
-
Power
Supply
9/17
<Page>
TDK-Lambda
ZWS300RC
INSTRUCTION MANUAL
Film Cap.
Electrolytic Cap.
R1
Oscilloscope
C3
Bandwidth : 100MHz
+V
-V
+V
-V
Series
+
load
-
+
load
-