Dimensions & Clearances - Valor Madrona MF28JLN NG Installation & Owner's Manual

Dv gas fireplace heater (engine only)
Table of Contents

Advertisement

Traditional Cast Stove MFCS01 (black) or Traditional Cast Stove MFCS02 (Majolica brown)
Suggested gas line
2" (52 mm)
4"
access point through wall.
minimum
(102 mm)
Route to avoid optional fan.
Pipe supplied with
engine (see engine
manual p. 18)
Gas line connection point
3/8" NPT FEMALE at valve
28-1/2 " (724 mm)
23"
(584 mm)
x
7-1/2"
Gas inlet position
(191 mm)
3/8" fem. NPT
27-1/2" (699 mm)
Min. 2"
between
combus-
tible wall
and stove
Corner clearances
Dimensions & Clearances
Ø 6-5/8"
venting
x
x
2"
(52 mm)
minimum
Sidewall
B
Min. 2" between
combustible wall
and stove
Mantel / shelf clearances
Mantel
0–1"
2–5"
Depth 'A'
(0–26 mm)
(51–127 mm)
Mantel
34"
36"
Height 'B'
(864 mm)
(914 mm)
A
Supplied with
top vent; field
convertible to
Mantel
rear vent
Ø 6-5/8"
venting
Centre of vent
14"
(356 mm)
17-7/8"
(454 mm)
32-1/2" minimum
Alcove clearances
QUALIFIED
INSTALLER
6–18"
19–24"
(152–457 mm)
(483–610 mm)
38"
42"
(965 mm)
(1067 mm)