1.8 -
TOOLS, MATERIALS AND
ADDITIONAL EQUIPMENT
For the installation and maintenance of the boiler you
will need:
-
Standard tools for space heating, gas and water fitting
-
Digital manometer that is capable of reading both positive
and negative pressures
-
Combustion analyzer
-
Digital multimeter
-
pH digital meter
-
Metric Allen wrenches
-
Metric socket wrenches
In addition, a handtruck with a fastening belt is useful.

1.9 - DISPOSAL

-
Dispose of the boiler packaging in an environmentally
sound manner.
-
Dispose of components of the heating system (e.g. boiler
or control device), that must be replaced in an environ-
mentally responsible manner.
Operating Limits of the boiler:
Max. boiler temperature: 176 °F (80 °C)
Max Allowable Working Temperature ASME: 200 °F
Max. Allowable Working Pressure ASME: 92 psi

1.10 - GENERAL WARNINGS

This instruction manual is an integral and indispensable
part of the product and must be retained by the person in
charge of the appliance.
Please read carefully the instructions contained in this manual
as they provide important indications regarding the safe
installation, use and servicing of this appliance.
Keep this manual in a safe place for future reference.
The installation and servicing must be carried out in
accordance with the regulations in force according to the
manufacturer's instructions and by legally competent
authorized persons.
The installations for the domestic hot water production
MUST be build, in their entirety, with materials (taps, pipes,
fittings, etc.) approved for drinkable water.
By a competent person, we imply a person who has a specific
technical qualification in the field of components for central
heating systems for domestic use, domestic hot water
production and servicing. The person must have the
qualifications foreseen by the current laws in force.
Bad or irregular servicing could compromise the safe
operation of the appliance, and could cause injury to persons,
animals or damage to property. The manufacturer shall not
be held liable for any such injury and/or damage.
Before carrying out any cleaning or servicing turn off the
electrical supply to the boiler by means of the ON/OFF switch
and/or by means of the appropriate shutdown devices.
General Information
Do not obstruct the intake/outlet terminal ducts.
In the event of failure and/or faulty functioning of the appliance,
switch off the boiler. Do not attempt to make any repairs:
contact qualified technicians.
Any repairs must be carried out by LATTNER authorized
technicians and using only original spare parts. Non-
observance of the above requirement may jeopardize the
safety of the appliance.
To guarantee the efficiency and correct functioning of the
appliance it is indispensable to have the boiler serviced
annually by a qualified person.
If the boiler remains unused for long periods, ensure that any
dangerous parts are rendered innocuous.
Before putting again into service an appliance which has been
unused for a certain time, proceed to rinse the domestic hot
water circuit, making the water flowing for the time necessary
to draw the full content of the domestic circuit.
If the appliance is sold or transferred to another owner or if
the present user moves home and leaves the appliance
installed, ensure yourself that the manual always follows the
appliance so that it can be consulted by the new owner and/
or installer.
Only original accessories must be used for all appliances
supplied with optionals or kits (including electrical ones).
This appliance must be used only for the purposes for which
it has been expressively designed. Any other use shall be
considered incorrect and therefore dangerous.