Panelbuilder Device Error Messages; Panelbuilder Translation Error Messages - Allen-Bradley 2755-SN3 Application Manual

Adaptascan bar code readers
Table of Contents

Advertisement

17–20
Communicating with PanelView 900t Terminals on a DeviceNet Network
Tag: <Tag Name> - Explicit Server Output Elements must be 0-63.
Tag: <Tag Name> - Data Type implies Packet Bytes should be equal to 2.
Certain PanelBuilder controls, however, may require additional bytes. If less
than 2 bytes are required, use Bit Array.
Tag: <Tag Name> - Data Type implies Packet Bytes should be equal to 4.
Certain PanelBuilder controls, however, may require additional bytes.
Tag: <Tag Name> - Data Type implies Packet Bytes should be less than or
equal to 2. Certain PanelBuilder controls, however, may require additional
bytes.
Tag: <Tag Name> - The length of the data extends beyond the size of the
packet.
Tag: <Tag Name> - The length of the data extends beyond the size of the
packet. Adjust Packet Bytes to at least #.
Tag: <Tag Name> - This tag cannot be assumed consistent or "atomic". The
tag's Message Type is inconsistent with previous tags in this group.
Tag: <Tag Name> - This tag cannot be assumed consistent or "atomic". The
Assembly Instance is inconsistent with the previous tags in this group.
Tag: <Tag Name> - This tag cannot be assumed consistent or "atomic". The
Peer's Class, Instance, Attribute, or Node Address is inconsistent with previous
tags in this group.
Device: <Device Name> - Cannot be converted to current protocol format.
Device: <Device Name> - Converted to DeviceNet. Default communication
parameters will be used.
Device: <Device Name> - Communication settings have never been initialized.
Too many peer accesses. Only 128 Explicit-Client message channels are
allowed per application.
Translation Failure
Publication 2755-6.8
Message

PanelBuilder Device Error Messages

Message

PanelBuilder Translation Error Messages

Message
Recommended Action
Reduce the word offset for the associated Tag Address.
Most PanelBuilder controls write only 1 element of data. If the
associated Data Type is an Unsigned Integer, this implies 2
bytes will be written by the Tag. However, if tags are assigned
to the Block Write of a Piloted Control List, the number of bytes
written will be a multiple of the states displayed on the list.
Most PanelBuilder controls write only 1 element of data. If the
associated Data Type is a Floating Point, this implies 4 bytes
will be written by the Tag. However, if tags are assigned to the
Block Write of a Piloted Control List, the number of bytes
written will be a multiple of the states displayed on the list.
Most PanelBuilder controls write only 1 element of data. If the
associated Data Type is an Bit Array, this implies at most 2
bytes will be written by the Tag. However, if tags are assigned
to the Block Write of a Piloted Control List, the number of bytes
written will be a multiple of the states displayed on the list.
If the associated tag is an I/O tag, increase either the Input or
Output Size. If the associated tag is Explicit-Server, the data
size extends beyond the 64 word limit of the Assembly
Instance.
Increase the Packet Bytes assigned to the tag.
Tags have been assigned to a PanelBuilder control that must
be updated in the same data packet. Change the Message
Type so that it is the same as other members of this group.
Tags have been assigned to a PanelBuilder control that must
be updated in the same data packet. Change the Assembly
Instance so that it is the same as the other members of this
group.
Tags have been assigned to a PanelBuilder control that must
be updated in the same data packet. Change the
Explicit-Client message so that it references the same peer
attribute as other tags assigned to this group.
Recommended Action
Create a new device entry under the Terminal Setup Dialog.
Update the Communications Setup Dialog to the appropriate
network values. (i.e. Node Address, Baud Rate, etc.)
Update the Communications Setup Dialog to the appropriate
network values. (i.e. Node Address, Baud Rate, etc.)
Recommended Action
Reduce the number of Explicit-Client Tags in your application.
Contact Allen-Bradley for technical support.