DeviceNet Application
Report
Error Messages and
Codes
Tag: <Tag Name> - Incomplete Address
Tag: <Tag Name> - Invalid Element Number
Tag: <Tag Name> - Expected Slash / in Tag Address
Tag: <Tag Name> - Invalid Bit Number. Bit number must be 0-15.
Tag: <Tag Name> - Expected Output Tag. Tag Address should begin with O.
Tag: <Tag Name> - Expected Input Tag. Tag Address should begin with I.
Tag: <Tag Name> - Input Element Extends Beyond Input Size.
Tag: <Tag Name> - Output Element Extends Beyond Output Size.
Tag: <Tag Name> - Expected Discrete Tag.
Tag: <Tag Name> - Expected Analog Tag.
Tag: <Tag Name> - Invalid Packet Length. Packet Length must be 1-128 bytes.
Tag: <Tag Name> - Cannot be converted to current protocol format.
Tag: <Tag Name> - Invalid Node Address. Node must be 0-63.
Tag: <Tag Name> - Invalid Bit Offset. Bit Offset must not extend beyond the
packet length.
Tag: <Tag Name> - Expected Read Tag.
Tag: <Tag Name> - Expected Write Tag.
Tag: <Tag Name> - Invalid Address Type. Address must begin with I or O.
Tag: <Tag Name> - Explicit Server Input and Output Tags have been assigned
to the same Assembly Instance.
Tag: <Tag Name> - Invalid Data Size. Data element extends beyond input or
output size.
Tag: <Tag Name> - Expected Colon. I or O should be followed by :
Tag: <Tag Name> - Bit Offset must be a multiple of 8 for Character Arrays.
Tag: <Tag Name> - Explicit Server Input Elements must be 0-63.
Communicating with PanelView 900t Terminals on a DeviceNet Network
The application printout for DeviceNet provides the following
information:
configuration data
tag data
supplemental data
The following tables lists error messages and codes specific to
DeviceNet communications. For all other messages, refer to the
PanelView and PanelBuilder user manuals.

PanelBuilder Tag Error Messages

Message
Table continued on the next page.
Recommended Action
Change the tag address so it is the following format:
I:<word>/<bit> or O:<word>/<bit>
where <bit> is required for Bit and Bit Array.
The Tag Address should have a numeric word offset.
Add a slash and bit number to the Tag Address
Change the bit number to a value between 0 and 15.
Change the Tag Address so it begins with an O.
Change the Tag Address so it begins with an I.
The word offset in the Tag Address must be less than the Input
Size specified on the Communications Setup Dialog.
The word offset in the Tag Address must be less than the
Output Size specified on the Communications Setup Dialog.
The Data Type implies that the Tag Address should specify a
bit number.
The Data Type implies that the Tag Address should not specify
a bit number.
Change packet bytes to 1-128 bytes.
This tag must be manually edited to the DeviceNet protocol.
DeviceNet node addresses must be 0-63.
Reduce the Bit Offset.
Uncheck the Write Tag box on the Tag Form.
Check the Write Tag box on the Tag Form.
Modify the Tag Address to begin with I or O.
An Assembly Instance can only be assigned all input tags or
output tags. Place input and output tags in separate assembly
instances.
Increase the input or output size on the terminal setup screen.
Add a colon : after the I or O.
Adjust the Bit Offset on the Tag Form.
Reduce the word offset for the associated Tag Address.