Before Using This System; Setting The Electrolysis Condition (Set By The Dealer) - Sanyo VW-VF10BG Technical Data & Service Manual

Floor-mounted model with virus washer function
Hide thumbs Also See for VW-VF10BG:
Table of Contents

Advertisement

1. Before Using this System

Checking the installation location
Do not install the system in the following locations:
G
Near curtains, or on carpets
These items can obstruct the intake and outlet, and can
cause system malfunction.
G
High locations, inclined locations, or unstable
locations
Human contact may cause the unit to fall or tip over. If the
unit is installed in an inclined location, the water level
sensor may be activated, causing the ADD WATER lamp to
light, stopping operation, and resulting in water leakage.
CAUTION
Be sure to connect the electrical ground wire.

1. Setting the electrolysis condition (set by the dealer)

1.
Press at the points marked "PUSH" on both sides at the top of the front upper panel, then pull the top
of the panel toward you to remove it.
G
When removing the front upper panel, take care not to drop it, and be careful
CAUTION
when setting it on the floor.
2.
It is necessary to set the optimal electrolysis condition for the tap water to be used by the Virus Washer
system. For this purpose, the dealer determines the chlorine ion concentration and the hardness of the
tap water, and sets the electrolysis condition according to the figure below.
Tap water with hardness of 400 ppm or more cannot be used because this level of hardness is too high.
Note: Chlorine ions differ from what is ordinarily referred to as "chlorine" (free chlorine).
They are salts in the water that have become ionized.
*1: In regions where the chlorine ion concentration is 5 ppm or less, add salt
to the water tank and use setting No. 7.
*2: Set the electrolysis condition according to the tap water that is used.
Tap water chlorine
Electrolysis
ion concentration
condition
5 < ¯ < 10 ppm
No. 6
10 < ¯ < 20 ppm
No. 5
(A pen or similar item is useful for turning the knob.)
(At the time of shipment, this knob is set to "5.")
Switch No.
0
Do not use this setting.
Use this setting if there is a strong odor.
1, 2
Ordinarily, this setting is not used.
3 – 6
These are the modes that are ordinarily used.
7
This is the mode for when salt is used.
8, 9
Do not use these settings.
G
In regions where the electrolysis condition is 7, turn the
electrolysis condition switch knob to "7" and add salt (1 g)
to the water tank. (Refer to "Adding salt.")
3.
Key points when setting the electrolysis condition
1) Room where smoking occurs
More electrolyzed water is consumed in these rooms, therefore electrolysis
condition "6" is recommended.
CAUTION
G
This system is not able to break down or remove toxic gasses and substances. Be sure to open a window or
otherwise ventilate the interior of the room in the event of a gas or chemical release.
G
If the system is used for a long period in a small room, open a window and ventilate the room as necessary.
Tap water chlorine
Electrolysis
ion concentration
condition
20 < ¯ < 30 ppm
30 < ¯ < 100 ppm
Purpose
2 - 2
Ensure the space around the unit that is shown
in the figure below.
Minimum
10 cm
1ø AC 220 – 240 V
2-pin plug
with grounding socket
No. 4
¯
: Chlorine ion
No. 3
concentration
Knob
Electrolysis condition
setting switch
0
Using this System
Minimum 100 cm
Minimum
10 cm
Minimum 100 cm