3. Replacing the circulation pump
1
Perform steps
1
–
2
Disconnect the circulation pump cord from the cord clip.
3
Cut the binding bands (2) inside the electrical component box, then open the cord clips (2) and disconnect the
circulation pump connector.
Circulation
pump connector
(DP)
4
Remove the installation screws (2) from the circulation pump installation bracket, then remove the circulation
pump together with the bracket.
5
Remove the screws (3) from the circulation pump installation bracket, then remove the circulation pump.
5
from "Replacing the electrolysis tank."
Screws
Circulation pump cord
Cord
clip
Cord clips
Circulation
pump
6 - 7
Maintenance Procedures
Binding
bands
Circulation
pump
installation
bracket
Circulation
pump
6