6
Replace the solenoid valve.
(1) Cut the binding bands (2) inside the electrical component box, then disconnect the solenoid valve
connector and remove the cord from the clamps (2).
Solenoid
valve
connector
(DRV1)
(2) Remove the solenoid valve installation bracket A (2 screws), then disconnect the transparent tube from the
left joint. Lift up the solenoid valve unit while pulling it out toward the front. (For the method used to
disconnect the transparent tube from the joint, refer to step
element.")
6
Screws
(3) Remove the solenoid valve from the installation bracket A (2 screws).
Clamps
Solenoid
valve
installation
bracket A
Joint
Screws
Solenoid valve installation bracket A
Cord clip
5
from "Replacing the Virus Washer
Solenoid valve
Joint
6 - 14
Maintenance Procedures
Binding
bands