Changing The Cleaning Monitor Display - Sanyo VW-VF10BG Technical Data & Service Manual

Floor-mounted model with virus washer function
Hide thumbs Also See for VW-VF10BG:
Table of Contents

Advertisement

4. Changing the Cleaning Monitor Display

The cleaning monitor display can be changed by means of setting item code "88" on the control PCB EEPROM.
Setting data
Use the maintenance remote control unit to change the cleaning monitor display.
(1) RCS-TM80BG (85978487)
(2) Wire K (8540528057900)
This operation must be performed when the system is stopped.
For the <Preparation for change> and <Procedure>, refer to "3. Turning the Buzzer ON/OFF."
<Cleaning monitor display>
(1) Setting data 00: Standard display (setting at time of shipment from the factory)
Unit status
Stopped
Operating
5
(2) Setting data 01: Humidity indicator (Displayed when the FILTER RESET SW is pressed.)
Unit status
Stopped
Operating
(3) Setting data 02: Blinking line display when cleaning indicator is full
Unit status
Operating
(4) Setting data 03: Blinking line display when humidity indicator and cleaning indicator are full.
00: Standard display (setting at time of shipment from the factory)
01: Humidity indicator
02: Blinking line display when cleaning indicator is full
03: Blinking line display when humidity indicator and cleaning indicator are full
Total airflow
0 – Less than 300 m
300 – Less than 600 m
600 – Less than 900 m
900 – Less than 1200 m
1200 – Less than 1500 m
3
1500 m
or more
Humidity
29 % or less
30 – 39 %
40 – 49 %
50 – 59 %
60 – 69 %
70 – 79 %
80 % or more
1 → 6 → 1 (Repeats)
1
2
3
4
5
6
3
3
3
3
3
(Blinking)
(Blinking)
5 - 7
PCB and Functions
TREATED AIR VOLUME
TREATED AIR VOLUME