(7)Lo uver Control
After energization, the swing motor will open the horizontal
louver to be open and then be close completely. And the air outlet is close.
In heating mode, if the swing function is not set, the horizontal
louver will rotate to maximum in clockwise direction. Then it will rotate
to place D. Under other state, the horizontal louver will rotate to
level L. If the swing function is set when starting the unit, the horizontal louver
will swing between place L and D. there are 7 states for the louver: in
Place L, Place A, Place B, Place C, Place D, and swing between Place L and
place D, stop in any place between Place L and place D. When the unit is
turned off, the louver will stay in place 0. The swing is available only
when the swing function is set and the indoor fan is running.
Note: When place L to B, place A to C, and place B and D is set, the horizontal
louver will swing between place L to D.
D
A
B
L
C
(8)Sleep Function
1. It is applicable to cooling mode, dry mode and heating mode.
2. In cooling mode or dry mode, 1 hour after the sleep curve is
set, the setting temperature will rise by 1
temperature will rise by 2
change any more
set
set
set
1h
2h
3. In heating mode, 1 hour after the sleep curve is set, the set temperature
will decrease by 1
. 2 hours later, the set temperature will decrease by
2
. After that, the set temperature will not change any more.
2h
1h
set
set
set
(9)Timer Function
The main board has general timer function and clock timer function. The timer
function can be selected by remote controller.
(1) General timer (timer-on and timer-off of the unit can be set.
The accuracy is minute.E.g.: timer on for 1 hour; timer off for 1.5 hours.)
Timer on: after setting timer on, the unit will run at set time according to
the original set mode. The timing interval is 0.5hour, and the set
range is 0.5~24hours.
L
A
B
C
D
. 2 hours later, the setting
. After that, the setting temperature will not
Set temp. T
set
About 2h
About 2h
Set temp. T
set
Timer off: the timer off function can be set when the unit is on. When the
set time for timer off is reached, the unit will stop. The timing interval is
0.5hour, and the set range is 0.5~24hours.
(2) Clock Timer (timer-on and timer-off of the unit can be set. The accuracy
is minute. E.g.: timer on at 8:00a.m.; timer off at 17:30p.m.)
Timer on: if the timer on function is set when the system is on, the unit
will keep running. If the timer on function is set when the unit is off, the
unit will start running at the previously set mode when the set time is
reached.
Timer off: if the timer off function is set when the unit is off, the unit
will keep off state even though the setting time is reached. If t he timer off
function is set when the unit is on, the unit will stop running when the
set time is reached.
Timer modification: when the unit is under timer state, start or stop of the
unit can be set via remote ON/OFF button and the timer can be reset. The
unit runs according to the latest set state.
When both the timer on and timer off are set: the system runs according to
the current set state. When the set time is reached, the unit will start
and stop running. In that case, the unit will run according to the previously
set mode when the set time for timer on is reached. The unit will stop
running while the set time for timer off is reached.
If the setting time for timer on and timer off is the same, the unit will stop
running no matter what the current state is.
(10)Auto-Restart Function
Memory: mode, vertical swing, light, set temperature, set fan speed,
general timer (not clock), Fahrenheit / Celsius. After de-energized, the unit
can operate according to the memory if it is energized again. If the timer
function is not set in the last remote control, the unit will operate according to
the last remote control. If the timer function is set in the last control before it
is de-energized, the unit will memorize the last timer setting. The set time is
recalculated since the energization of the unit. If the timer function is set in
the last control and the setting time is reached before the unit is de-
energized, the unit will operate according to the previous running mode after
it is energized again. But the timer function will terminate. The clock will
not be memorized.
(11) Turbo Function
In cooling and heating mode (not available in auto, dry, fan mode),
press the Turbo button, the super high speed will be displayed in the
remote controller and the indoor fan cha nges to super high speed as well.
(12) HEALTH Function
When the indoor fan is running, the HEALTH function is set by pressing
remote controller (If there is no Health button on the remote controller, the
start of HEALTH function is defaulted).
(13) I FEEL Function
If the remote controller receives the I FEEL order, the controller will work
according to the ambient temp which is sent by remote controller (Except the
defrosting and cool air prevention, which still adopt the sampling value from
AC itself ambient temp sensor), the remote controller will send ambient
temperature value to controller at intervals. If the controller hasn't received
the ambient temperature value from the remote controller for long time, then
it will run accroding to the current ambient temperature of AC. If the
function has not been set, the ambient temperature will adopt the sensor
sampling value of AC itself. If power off happens, this function will not be
memorized.