Checking For Clearance Of Combustion - Flavel Emberglow Classic RC User Manual

Flavel radiant convector gas fire
Table of Contents

Advertisement

IMPORTANT: THE FIRE MUST ONLY BE OPERATED WITH THE FRONT
CASTING IN PLACE
3.5
CHECKING FOR CLEARANCE OF COMBUSTION PRODUCTS
a)
Close all doors and windows in the room.
b)
Light the fire and turn to the maximum position.
After 5 minutes hold the smoke match as shown in Fig. 17 below.
Whilst holding the smoke match in the correct position, approximately
25mm below the lower edge of the draught diverter, ensure that most of
the smoke is drawn into the flue aperture. If in doubt repeat the
exercise after a further 5/10 minutes.
Note:-
It is recommended that the smoke match is fitted into an approved
smoke match holder, when checking for clearance of combustion
products.
Fig. 17
If there is an extractor fan fitted in a joining room, then the spillage test must be
repeated with the fan switched on and running at maximum speed. All
interconnecting doors must be opened in accordance with the latest issue of BS
5440.
IF SPILLAGE IS DETECTED
The cause must be discovered and the fault corrected. If the fault cannot be cor-
rected disconnect the appliance from the gas supply and seek expert advice.
Possible causes of spillage from the appliance are:- chimney restriction, down
draught or insufficient air supply to the room.
c)
After ensuring that the fire is safe to use it should be left on "High"
position to fully warm up. During this time a slight odour may be
noticed, this is due to the "newness" of the fire and will soon disappear.
45 degrees
19
Smoke Match position -
Approximately 25mm
below and from left
hand edge of draught
diverter (viewed from
rear for clarity of image)
Smoke match holder to be
inserted at approximely 45
degree angle below side
trim