Lexmark MS312 Service Manual page 47

Machine type 4514-330
Hide thumbs Also See for MS312:
Table of Contents

Advertisement

Error code
Description
200.84
Image data did not start on time.
200.87
During warm up flush, sheet detected too long over
input sensor.
Sensor (input) static jam service check
Action
Step 1
Check the input sensor area for jammed media fragments.
Is the paper path free of partially fed or jammed media?
Step 2
Check the jam access cover if it is blocking the input sensor.
Is it blocking the input sensor?
Step 3
Check the input sensor cable for proper connection.
Is it properly connected?
Step 4
POR into the Diagnostics menu and perform a sensor test:
Diagnostics Menu > Base Sensor Test > Input.
Does the sensor state on the control panel display change when it is
toggled?
Step 5
Does the error remain?
Action
Go to
"Sensor (input) image jam service check" on
page
49.
Go to
"Sensor (input) early/late arriving service
check" on page
Yes
Go to step 2.
Replace the jam access
cover. See
cover removal" on
page
Go to step 4.
Go to step 5.
Contact the next level
of support.
Diagnostic information
47
48.
No
Clear the paper path of
any media fragments.
Go to step 3.
"Jam access
199.
Reseat the cable.
Replace the input
sensor. See
sensor and input
sensor removal" on
page
211.
The problem is solved.
4514
"Duplex

Advertisement

Table of Contents
loading

Table of Contents