JUKI LK-1900B/IP-420 Instruction Manual page 83

Table of Contents

Advertisement

Error code
Display
E905
E907
E908
E910
E913
E914
E915
E916
E917
Description of error
Heat sink temperature
for SERVO CONTROL p.
c. b. abnormality
Turn ON the power again
after taking overheat time
of SERVO CONTROL p. c.
b.
X feed motor origin
retrieval error
When origin sensor signal
is not inputted at the time
of origin retrieval motion.
Y feed motor origin
retrieval error
When origin sensor signal
is not inputted at the time
of origin retrieval motion.
Presser motor origin
retrieval error
When origin sensor signal
is not inputted at the time
of origin retrieval motion.
Thread clamp origin
retrieval error
When origin sensor signal
is not inputted at the time
of origin retrieval motion.
Feed defective error
Timing lag between feed
and main shaft occurs.
Communication
abnormality between
operation panel and
MAIN CPU
When abnormality occurs
in data communication.
Communication
abnormality between
MAIN CPU and main
shaft CPU
When abnormality occurs
in data communication.
Communication failure
between operation panel
and personal computer
When abnormality occurs
in data communication.
– 79 –
Display message
How to recover
Turn OFF the
power.
Turn OFF the
power.
Turn OFF the
power.
Turn OFF the
power.
Turn OFF the
power.
Turn OFF
the power.
Turn OFF
the power.
Turn OFF
the power.
Possible to re-
start after reset.
Place of
recovery

Hide quick links: