Fireplace/Surround Suitability; Shelf Position; Side Clearance; Closure Plate - Flavel Emberglow Classic FEMC00MN Installation And Maintenance Instructions Manual

Radiant convector gas fire
Table of Contents

Advertisement

1.3
FIREPLACE / SURROUND SUITABILITY
The fire is suitable for hearth mounting or wall mounting. It must not be fitted
directly onto a carpet or other combustible material. It must not be fitted to com-
bustible walls.
This fire is suitable for the following hearth / surround types:
Non-combustible hearths / surrounds.
Purpose made proprietary hearths / surrounds with a minimum temperature rating
of 150 o C.
If a heating appliance is fitted directly against a wall without the use of a fire-
place or fire surround, soft wall coverings such as wallpaper, blown vinyl,
etc. could be affected by the heat and may, therefore scorch or become dis-
coloured. Please bear this in mind when installing or decorating.
1.4

SHELF POSITION

The fire may be fitted below a combustible shelf providing there is a minimum
distance of 200 mm above the top of the fire and the shelf does not project more
than 150 mm. If the shelf overhangs more than 150 mm the distance between the
fire and the shelf must be increased by 25 mm for every 25 mm of additional over-
hang over 150 mm.
1.5

SIDE CLEARANCE

A minimum clearance of 100mm should be allowed on either side of the fire for
servicing. Any fire surround uprights should not project forward by more than
100mm.
NOTE. The fire must be installed so that no part of a combustible side wall when
measured laterally is less than 500mm from the radiants.
1.6

CLOSURE PLATE

A closure plate is supplied with this fire and must be fitted. The closure plate must
be sealed to the fireplace or surround opening with suitable adhesive tape. See
section 2.2.2
1.7
FLUE / CHIMNEY INSPECTION
Before commencing installation, a flue or chimney should be inspected to ensure
that all the following conditions are satisfied.
a)
Check that the chimney / flue only serves one fireplace and is clear of
any obstruction. Any obstruction. Any dampers or register plates must
be removed or locked in the open position.
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Emberglow classic femc00mpFemc00mn g20Femc00mp g31

Table of Contents