Tested and approved for wood pellets and or a mixture of
up to 50% shelled field corn mixed with a minimum of 50%
wood pellets, burning of any other type of fuel voids your
warranty. When burning pellet/corn blends more frequent
cleanings may be required.
!
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
• Contact local building or fire officials about restrictions
and installation inspection requirements in your area.
1
Owner's Manual

Care and Operation

CAUTION
CAUTION
Harman® • Accentra 52i Owner's Manual_R19 • 2013 -___ • 03/16
!
Please read this entire manual before
installation and use of this pellet fuel-
burning room heater.
Failure to follow these instructions could
result in property damage, bodily injury
or even death.
• Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
• Do not overfire - If any external part starts to glow, you
are overfiring. Reduce feed rate. Overfiring will void
your warranty.
• Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause house fire.
!
HOT SURFACES!
Glass and other surfaces are hot during
operation and cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
stove.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other
flammable materials.
• Keep clothing, furniture, draperies and other flammable
materials away.
NOTE
To obtain a French translation of this manual, please
contact your dealer or visit www.harmanstoves.com
Pour obtenir une traduction française de ce manuel, s'il
vous plaît contacter votre revendeur ou visitez www.
harmanstoves.com
WARNING
WARNING
3-90-00574c

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Accentra 52i Pellet Insert and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Harman Accentra 52i Pellet Insert

  • Page 1: Care And Operation

    • Installation MUST comply with local, regional, state and national codes and regulations. Pour obtenir une traduction française de ce manuel, s’il • Contact local building or fire officials about restrictions vous plaît contacter votre revendeur ou visitez www. and installation inspection requirements in your area. harmanstoves.com Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 2: Welcome

    2016 2017 2018 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC Manufactured by / Fabriqué par: Hearth and Home Technologies 352 Mountain House Road, Halifax PA 17032 3-90-00575 Rev E Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c LABEL TICKET ECO:...
  • Page 3: Table Of Contents

    H. Pellet Feeder Chamber ......20 Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16...
  • Page 4: Limited Lifetime Warranty

    7 years 3 years HHT chimney and termination 1 year Burners, logs and refractory years Limited 3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645F 02-18-13 Page 1 of 2 Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 5: B. Limited Lifetime Warranty

    The appliance is subjected to prolonged periods of dampness or condensation. • There is any damage to the appliance or other components due to water or weather damage which is the result of, but not limited to, improper chimney or venting installation. LIMITATIONS OF LIABILITY: • The owner’s exclusive remedy and HHT’s sole obligation under this warranty, under any other warranty, express or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above. In no event will HHT be liable for any incidental or consequential damages caused by defects in the appliance. Some states do not allow exclusions or limitation of incidental or consequential damages, so these limitations may not apply to you. This warranty gives you specific rights; you may also have other rights, which vary from state to state. EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645F 02-18-13 Page 2 of 2 Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 6: Product Specific And Important Safety Information

    120 VAC, 60 Hz, Start 5.0 Amps, Run 4.0 Amps NOTE: Some generator or battery back-up systems may not be compatible with the micro-processor electronics on this appliance. Please consult the power supply manufacturer for compatible systems. Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 7: Btu & Efficiency Specifications

    This wood heater needs periodic inspection and repair for proper operation. It is against federal regulations to operate this wood heater in a manner inconsistent with operating instructions in this manual. Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 8: General Information

    Contact your dealer for more information, or visit: www. hpba.org/safety-information. To prevent unintended operation when not using your stove for an extended period of time (summer months, vacations, trips, etc): • Unplug stove from receptacle. Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 9: Control Explanation

    Stove Temp Mode, blower speed by turning the knob to the Dealers exclusively. using the inner scale marked from 1 to 7. high or low side of each mode. Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 10: Fuel Specification

    Tested and approved for use with wood pellets ONLY. Burning of any other fuel will void your warranty. NOTICE Hearth & Home Technologies is not responsible for stove performance or extra maintenance required as a result of using fuel with higher ash or mineral content. Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 11: General Operating Information

    THE FIRE. • Combustible materials may ignite. Before Your First Fire 1. First, make sure your appliance has been properly installed and that all safety requirements have been met. Pay particular attention to the fire protection and venting instructions. 2. Double check that the ash pan and firebox are empty! 3. Close the front door. Figure 3.1 Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 12: Operating Instructions

    • With appliance door open. • Hopper Lid open. Do NOT store fuel: • Closer than required clearances to combustibles to appliance • Within space required for loading or ash removal. Figure 4.4 Figure 4.5 Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 13: Automatic Ignition

    1" or less ash bed is not obtainable, it is not a problem. The 1" ash bed is only at maximum burn rate and during normal operation, the ash bed will be larger. Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 14: E. Automatic Ignition

    This setting will produce continuous maximum heat output with the distribution blower at full speed. Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 15: Proper Shutdown Procedure

    More frequently depending on the fuel type NOTICE: These are recommendations. Clean more frequently if you encounter heavy build-up of ash at the recommended interval or you see soot coming from the vent. Not properly cleaning your appliance on a regular basis will void your warranty. Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 16: Glass Maintenance

    Install the self adhesive 1/4"” gasket material around the front face of the glass. Set the glass panel and gasket gently onto the door. Install the hold down clips and tighten with bolts. Glass - Cleaning Sometimes it will be necessary to clean accumulated ash from the glass surface; allowing this ash to remain on the glass for long periods can result in “etching” due to the acidity of the ash. Never clean the glass while it is hot, and do not use abrasive substances. Wash the surface with cool water, and rinse thoroughly. You may wish to use a non-abrasive cleaner specifically designed for use on stove glass. In any case, dry thoroughly before relighting your stove. Replace glass only with high temperature ceramic glass. Inspect door gasket during cleaning and inspection Glass Gasket Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 17: Burnpot Maintenance

    Note: The hot lead/cold lead connection must always Figure 5.3 be pulled to the rear of the feeder body before operation. Viewed from below through the ash pan opening. Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 18: Heat Exchanger Maintenance

    4. Tip the top of the heat exchanger toward the door opening until it can be lifted up and out. Figure 5.5a Brush the firebox free of remaining Fly-Ash. Figure 5.7 Figure 5.5 Latch Figure 5.5a Lifting tab Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 19: Combustion Blower Chamber

    Cleanout Combustion Cover Figure 5.8 it into place. Once combustion cover assembly is removed you now have access to clean the combustion blower chamber area. Figure 5.11. Lower Combustion Chamber Combustion Cover Assembly Figure 5.9 Upper Combustion Chamber Figure 5.11 Combustion Cover Latch Figure 5.10 Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 20: Pellet Feeder Chamber

    NOTE: Views are shown with the exhaust tube and covers removed for better viewing. Feeder clean out cover 5/16" Wing Nut Figure 5.13 Pellet Metering Possible pellet fines Slide Plate buildup area. Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 21: Troubleshooting And Frequently Asked Questions

    * Manual reset - disconnect power cord for a few seconds automatically reset. and reconnect. If error still occurs call your Dealer. NOTE: Unit will not start in "AUTO" with this status error. 5 Blinks (In Igniter Auto. Mode Only): Indicates that the unit has failed to light within the 36 minute start cycle. To reset - Turn Mode Selector to "OFF", then turn to either mode again.) Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 22: Frequently Asked Questions

    7. This is normal. Flame will settle down once the fire is established. Contact your dealer for additional information regarding operation and troubleshooting. Visit www.harmanstoves. com to find a dealer. Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 23: Troubleshooting

    Fuel should not be stored within the stove installation 1. No fuel in hopper. clearances or within the space required for charging and 2. Draft is too low, blocked flue. ash removal. 3. Something is restricting fuel flow. 4. Feed motor or combustion blower has failed. Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 24: Reference Materials

    FUELS AND OPERATION GUIDELINES fire department, shut down the stove, and evacuate the residence. Before using the appliance, have the venting system thoroughly inspected and replace any damaged components. Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 25: Motor And Component Location

    Sensor for faults. If a fault should occur, the control sends a status is connected into the AC (high voltage) wiring. alert and at the same time the unit goes down to minimum feed/ minimum burn as a safety condition. In the event of component failure, replace component(s) equivalent to the original. See Service Parts section of this manual. Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 26: Loss Of Power

    4. Light pellet gel with a match, and close the door, turn Mode • If the fire is still burning, it will resume normal Selector to Constant Burn. Operation will begin when the operation. fire reaches the proper temperature. Contact your dealer if you have questions about UPS compatibility with your appliance. Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 27: Service Parts

    22” Hopper: 24” Hopper: 1-90-574200-1 (Black) 1-90-574220-1 (Black) 1-90-574240-1 (Black) 1-90-574200-14 (Majolica Brown) 1-90-574220-14 (Majolica Brown) 1-90-574240-14 (Majolica Brown) 27 28 Part number list on following page. 10/15 Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 28 1-00-574345 Label, Large Caution 3-90-08416 Black Paint 4-00-574319P Cast Top Majolica Brown 1-10-574319-14 Black Paint 4-00-574321P Cast Wing Left Majolica Brown 1-10-574321-14 Additional service parts on following page. Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 29 Spring Latches with hardware Set of 2 1-00-00927 Burn Pot Gasket Pkg of 5 1-00-07381 Distribution Blower Qty 2 req 3-21-33647 Additional service parts on following page. Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 30 Majolica Brown 1-00-0014 Wiring Harness 3-20-08727 DK blue pigtail 3-20-574122 Sky blue pigtail 3-20-574123 Hardware Pack 1-00-574439 Smoke Shield w/HDWR Post 008263307 1-00-574430 Additional service parts on following page. Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 31 3-44-677160-10 Feeder Air Crossover Kit 1-00-67900 8.14 9MM Silicone Tube 5 Ft 1-00-511427 8.15 Pellet Air Intake Assembly 1-10-06810A Gasket Feeder Air Intake Pkg of 6 3-44-72224-6 8.16 Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...
  • Page 32: Contact Information

    Printed in U.S.A. - Copyright 2013 Harman® • Accentra 52i Owner’s Manual_R19 • 2013 -___ • 03/16 3-90-00574c...

Table of Contents

Save PDF