#4 Screws
FIG. 4
MXD-700 Backbox Installation (Landscape)
6. Push the Backbox into the mounting surface. Insure that the locking tabs lie flush against
the Backbox and that the Backbox goes freely into the opening.
7. Extend the locking tabs on the sides of the Backbox by tightening the screws inside the
box until snug.
Apply enough pressure to the screw head to keep the box flush with the wall: this
ensures that the locking tabs will tighten up against the inside of the wall.
The Backbox is clear to allow visual confirmation that the tabs have been extended and
are gripping the wall, as well as in assisting with removal if necessary.
Note: The maximum recommended torque to screw in the locking tabs on the Backbox is
5 IN-LB [56 N-CM]. Applying excessive torque while tightening the tab screws, such as
with powered screwdrivers, can strip out the locking tabs or damage the Backbox.
8. For additional strength, #4 mounting screws (not included) may be secured via mounting
holes located at the left and right sides of the MXD-700 (FIG. 4).
In order to prevent damage to the touch panel, make sure that these are flush with the
Backbox.
9. Insert each connector into its corresponding location along the back of the device. To
reach the RJ45 connector, gently pull it from beneath the electronics cover. Attach the
Ethernet cable and gently push the connection back under the cover.
Note: To facilitate connection of the RJ45 connector to the Ethernet cable, press the
RJ45's cable into the RJ45 cable clip to hold it in a stable position. Make sure to remove
the cable from the cable clip before continuing the rest of the installation.
10. Test the incoming wiring by attaching the panel connections to their terminal locations
and applying power. Verify that the panel is receiving power and functioning properly to
prevent repetition of the installation.
Note: Do not disconnect the connectors from the touch panel. The unit must be installed
with the attached connectors before being inserted into the mounting surface.
Remove power before continuing with the installation.
11. Latch the panel onto the top hooks on the Backbox and push it down (Landscape) onto
the bottom snaps or on the left side and push it to the right (Portrait) (FIG. 5).
Press gently but firmly on the ends until the snaps "click" to lock it down.
Mounting Surface
Backbox
FIG. 5
Installing the MXD-700
WARNING: If you see a gap between the panel and the Backbox, or feel any binding while
locking down the panel, stop immediately and verify that no cables or other items are in the
way. Do not force the panel into position, as this can cause damage to the touch screen or
the panel electronics.
12. Reconnect the terminal Ethernet and USB to their respective locations on the Ethernet
port.
For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).
©2014 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com
2X Installation Clamp
for Wall Thickness
.37 [12.03] to .98 [.25.0]
4X Knock-Outs
Remove for Cable
Routing as Needed
Latch Hooks
Snaps
8/14
AMX reserves the right to alter specifications without notice at any time.
Powering On/Off X Series Panels
Modero X Series touch panels may be powered on by touching and holding the Sleep button.
To power off the panel, press and hold the Sleep button, and select Power Off on the on-
screen menu (FIG. 6):
FIG. 6
Sleep Button - Press and hold to access Power Off/Settings options

Configuration and Programming

X Series touch panels are equipped with a Settings menu that provides the ability to
configure various features on the panels.
To access the Settings menu, press and hold the Sleep button, and select Settings.
Note: Information on the Settings menu, panel configuration, and programming is provided in
the Modero X Series Programming Guide, available at www.amx.com.
Setting the Panel's Device Number and Device Name
1. In the Settings menu, select NetLinx. This opens a password keypad.
2. Enter the panel password into the keypad (the default is 1988) and select OK to access
the NetLinx page.
3. Press Device Number to open the NetLinx editing window.
4. Enter a unique Device Number assignment for the panel and press OK.
5. Enter a unique Device Name assignment for the panel and press OK.
Configuring the Panel's IP Address
These steps configure the panel to communicate with a network; it is still necessary to
connect to the NetLinx Master (see Connecting to a NetLinx Master below).
Network Communication via DHCP
1. In the Ethernet page, press DHCP/Static field to open the DHCP/Static window. Note
that DHCP is the default setting.
2. Select Host Name, enter the new host name
3. Press OK to save changes.
Network Communication via Static Address
1. In the Ethernet page, press DHCP/Static to open the DHCP/Static window.
2. Select Static to open the Static IP window.
3. Press any field to open a keypad or keyboard (depending on the field), and enter the
appropriate network address information.
4. Press OK to save your changes and return to the Ethernet page.
Connecting to a NetLinx Master
To establish the type of connection to make between the panel and the NetLinx Master:
1. In the NetLinx page, press Mode to choose the connection mode (URL, Listen or Auto):
Connection Modes
Mode
Description
URL
The device connects to the
target Master's IP address
via a TCP connection.
Listen
This mode allows the panel
to "listen" for the Master's
communication signals.
Note that in this mode, the
System Number and Master
IP/URL fields are read-only.
Auto
Use this mode when both
the panel and the NetLinx
Master are on the same
Subnet.
2. If password security is enabled on the target Master, enter the Username and
Password:
a.
Select Username to open the NetLinx window.
b.
Enter the Username and Password required by the Master.
c.
Press OK to save changes and return to the NetLinx page.
Related Software and Additional Documentation (at www.amx.com)
Programming the Modero X Series touch panels requires the use of the latest versions
of NetLinx Studio and TPDesign4, both available to download at www.amx.com. Refer
to the NetLinx Studio and TPDesign4 online help for information.
For additional information on the MXD-700 panel, refer to the X-Series Touch Panels
MXD/T-1000, MXD/T-700 & MXD-430 Instruction Manual.
For detailed information on the Settings menu as well programming information and
instructions on upgrading firmware, refer to the Modero X Series Programming Guide.
Procedures
1) Select URL in the Mode menu.
2) Enter the Master IP/URL, Master Port Number,
and Username/Password (if required by the
Master).
Press OK to save changes.
1) Select Listen in the Mode menu.
2) Confirm the panel's IP address is on the
Master's URL list (via NetLinx Studio).
3) Press OK to save changes.
Note: The Host Name (set on the Ethernet page),
can be used to locate the panel on the Master
(particularly useful for DHCP connections where
the IP address can change).
1) Select Auto in the Mode menu.
2) Enter the System Number and Username and
Password (if applicable).
3) Press OK to save changes.