System Layout; Bus Connection - Qvis APOIR-PTZ23 User Manual

23x zoom analogue ptz camera
Table of Contents

Advertisement

Alarm port
Name
Alarm out:1
GND
Alarm in:1-2
Please refer to the label for detailed connection information.

9.2 System Layout

9.2.1 BUS connection

Please refer to
Figure
© Copyright Qvis® All documentation rights reserved.
Function
One alarm output channel. When the alarm is triggered whilst in
the current channel, system will either activate the relay or not.
Alarm output relay default setup is NO.
For the default setup: 1-channel alarm output and 2-channel
alarm output is optional.
Alarm input ground end.
2-channel alarm input channels. This is to receive relay signal
from the external alarm source. You can go to dome menu to
activate specified preset or patter.
When the activation mode is set to 'NO' (normal open), dome
alarms when there is low voltage running along the line. High
voltage will not activate the alarm.
When the activation mode is set to 'NC' (normal close), dome
alarms when there is high voltage running along the line. Low
voltage will not activate the alarm.
Note:
Dome alarm input message is in ground mode.
Dome alarm input signal are in two modes: normal open and
normal close.
For the default setup: 2-channel alarm input and 7-channel
alarm input is optional.
9-1
and Figure 9-2 for BUS cable connection.
Figure 9-1
22