Gas Line Pipe Sizing - Temco ADF3310N-4 Operating Instructions Manual

Vent-free gas fireplaces
Table of Contents

Advertisement

NOTE: To determine the size of the branch gas line from the main gas line to the fireplace, enter the tables below (for iron
pipe or copper tubing) using the distance from the gas meter or second stage regulator to the furthest appliance on the
gas system. Select a pipe or tube diameter which has enough capacity to meet the maximum input requirement of the
fireplace. Regardless, do not use less than 1/2" diameter for the branch line. For any distances required longer than
shown in these tables, refer to the National Fuel Gas Code.
NOTE: There may be a local gas utility requirement specifying a minimum diameter for gas piping. All units require a 1/2 inch pipe
connection at the gas valve.
Length
of
1/2" D
Pipe
Natural
20'
92
30'
73
40'
63
50'
56
60'
50
70'
46
90'
40
100'
38
Tubing Length
Feet
10
20
30
40
50
60
80
100
WARNING: Use only internally tinned copper tubing. If correct copper tubing is not used, tubing can deteriorate and
develop gas leaks.
Position the top log so the hole on the bottom fits
over the peg on top of the rear log. The top log is
positioned correctly when it extends over the portion
of the burner that has a single row of ports (holes).
If the top log extends over a slotted row of ports, it is
not in the correct positon.
CAUTION: Proper log location is critical for
trouble-free operation. Ensure that the front and
back log are centered in the grate and are vertical
as seen from the side. There must be no impinge-
ment of the flames from the burner on any log.
78623

Gas Line Pipe Sizing

CAPACITY OF PIPING
Cubic Feet per Hour based on 0.3" w.c. Pressure Drop
Specific Gravity for Natural Gas - 0.6 (1000 BTU/Cubic Foot)
Specific Gravity for Propane Gas - 1.6 (2550 BTU/Cubic Foot)
Nominal Inches for Iron Pipe Sizes (1,000s BTU/hr)
3/4" D
Propane
Natural
Propane
143
190
296
115
152
237
97
130
202
87
115
179
79
105
163
71
96
151
61
84
130
59
79
122
Outside Diameter Copper Tubing, Type L (1,000s BTU/hr)
1/2"
0.43
110
76
61
52
46
42
36
32
1" D
Natural
Propane
Natural
350
546
730
285
444
590
245
380
500
215
334
440
196
304
400
180
280
370
160
250
320
150
235
305
5/8"
3/4"
0.545
0.666
206
348
141
239
114
192
97
164
86
146
78
132
67
113
59
100
Decorative Volcanic Ash
The volcanic ash provided should be sprinkled on the
hearth pan and up to the front burner shield. Do not
sprinkle volcanic ash around or on the burner or logs.
WARNING: Failure to position the parts in accor-
dance with this diagram or failure to use only
parts specifically approved with this heater may
result in property damage or personal injury. Do
not alter logs!
Temco ADF3310 Series
1¹⁄₄" D
1¹⁄₂" D
Propane Natural
Propane
1135
1100
918
890
778
760
683
670
622
610
576
560
497
490
474
460
7/8"
0.785
536
368
296
256
224
203
174
154
1711
1385
1183
1043
949
872
763
717