Gas Connection - Temco ADF3310N-4 Operating Instructions Manual

Vent-free gas fireplaces
Table of Contents

Advertisement

Pins Securing Top of
Screen Panel
T145
Fig. 7 To remove screen panel, remove two screws securing
screen, then pull panel down until top pins clear holes in top
of fireplace.
WARNING: The front screen must be installed
before the fireplace is put into operation.

Gas Connection

Gas Specifications
Model
ADF3310N-4
ADF3310P-4
LP/Propane
Check Gas Type. Use only the gas type indicated on
the heater's rating plate. If the gas type indicated on
the plate is not your type of gas supply, DO NOT
INSTALL. Contact your dealer for proper model.
Gas Piping. The gas supply line must be of an ad-
equate size to handle the BTU/HR requirements and
length of the run for the unit being installed.
Determine the minimum pipe size from the piping size
chart on Page 10. The normal gas connection is 1/2"
NPT made at the center of the unit.
WARNING
DANGER OF PROPERTY DAMAGE,
BODILY INJURY OR DEATH.
Make sure the heater is equipped to operate on
the type of gas available. Models designated as
natural gas are to be used with natural gas only.
Heaters designated for use with liquefied petro-
leum (LP) gas have orifices sized for commer-
cially pure propane gas. They cannot be used
with butane or a mixture of butane and propane.
Always use an external regulator for all LP appliances
to reduce the supply tank pressure to a maximum of
13" w.c. This is in addition to the regulator fitted to the
heater.
78623
Screws Securing Bottom of
Screen Panel
(Control Panel Door is Open)
Fuel
BTU/Hr
Natural
10,000
10,000
WARNING: Connecting directly to an unregulated
LP tank can cause an explosion.
All piping must comply with local codes and ordinances
or with the National Fuel Gas Code (ANSI Z223.1),
whichever applies. Installation of a sediment trap is a
requirement of this code.
Gas Connection. If installation is for L.P. gas, have
L.P. installer use two-stage regulation and make all
connections from the storage tank to the heater. Refer
to the National Fuel Gas Code for the proper supply
tank size with the Btu's/Hr requirements. If this is the
ONLY gas appliance, we recommend a minimum 200
pound cylinder with a fill gauge. Use of a 100 pound
cylinder is not recommended. Other household gas
appliances may require the tank size to be larger. Do
not operate the vent free fireplace if the fuel level in the
propane tank is below 1/4 full.
Use pipe wrenches when making the connection to the
valve to prevent turning or damage to gas valve.
WARNING
DANGER OF PROPERTY DAMAGE,
BODILY INJURY OR DEATH.
Never use a match or open flame to test for
leaks. Never exceed specified pressures for
testing. High pressures may damage the appli-
ance regulator which would require replacement.
Liquified petroleum (LP) is heavier than air and it
will settle in any low area, including open de-
pressions and it will remain there unless area is
ventilatedNever attempt start-up of unit before
thoroughly ventilating area.
Connection between the manual shut-off valve and the
gas valve can be made with a CSA design certified
flexible connector if allowed by local codes. A drip leg is
still required. Tighten all joints securely.
NOTE: If the manual gas shut-off valve is located in
the control compartment, the two screws that hold the
control cover in place during shipping must be left out
so the control cover is removable by hand.
Testing the Gas Piping. Test all piping for leaks.
When checking gas piping to the heater with gas
pressure less than 1/2 psi, shut off manual gas valve for
the heater.
If gas piping is to be checked with the pressure at or
above 1/2 psi, the heater and manual shut off valve
must be disconnected during testing to prevent damage
to the regulator on the unit, (see WARNING).
To ensure that the gas lines and connections do not
have any leaks, a pressure test should be performed.
Only a qualified installer should perform the pres-
sure test to ensure that the unit is not damaged by
Temco ADF3310 Series